A1000
76
532210 04 - Rev.A
S1
S4
Tr
ansla
tion of the original instruc
tions
ENGLISH
INTERLOCK WITH MEMORY
With 2 sensors, the other door opens automatically.
Two buttons can be used between the 2 doors to avoid trapping
(optional).
Use one-direction radar detectors
S1
S4
Req A1=1
Req A2=1
A1 closed
A2 closed
Open A1
Req A2=1
Open A2
Req A1=1
Req A1=0
Open A1
Req A2=0
Open A2
A1 mov.
A2 closed
Open A1
Req A2=1
Req (A1=1)
----
----
A1 closed
A2 mov.
Req A1=1
Req (A2=1)
Open A2
Req A1=1
----
----
A1 mov.
A2 mov
----
----
----
----
ReqA1=1 means that a request has been made to open A1
ReqA2=1 means that a request has been made to open A2
A1
A2
EXTERNAL
INTERNAL
SLAVE
MASTER
OPEN
EXTERNAL
OPEN
INTERNAL
BUTTON
OPEN
EXTERNAL
BUTTON
OPEN
INTERNAL