A1000
68
532210 04 - Rev.A
Tr
ansla
tion of the original instruc
tions
ENGLISH
Indication
Intervention required
41
41
Date and time missing
Reset date/time via the SDK EVO.
42
42
Clock battery
discharged or missing
Replace the battery to avoid losing the time in case of mains power failure.
44
44
Emergency
active
Indicates that an emergency is active
45
45
Timer
active
the TIMER is activated
46
46
Timer
function in progress
A TIMER function is running
47
47
Last movement carried out with battery
The board has carried out the last programmed movement using the battery.
48
48
Night-time
mode operation
Night-time mode operation.
49
49
Manual
mode operation
Manual mode operation
50
50
Partial
mode operation
Partial mode operation
51
51
Obstacle during closure
detected
The door opens again. Check for an obstacle in closing
52
52
Obstacle during opening
detected
After 5 sec. the door attempts another opening.
Check for an obstacle in opening.
53
53
Number of maintenance cycles corrupted
Replace the board and carry out maintenance on the system.
54
54
Motor block
absorption fault
Perform RESET. Check the motor block
55
55
Operation in
pharmacy
mode in progress
PHARMACY opening is in progress.
56
56
Battery
operation
the indication remains as long as the automation operates on battery with mains power
supply down.
57
57
Searching for strike on opening
the indication remains as long as the stage is ongoing
58
58
Searching for strike on closing
the indication remains as long as the stage is ongoing
59
59
Motor block
fault (only with Monitoring Kit)
Perform RESET. If the problem persists replace the motor block.
60
60
Maintenance requested
Ordinary or periodic maintenance request.
61
61
SDK EVO
/ LK EVO / KS EVO
fault
Check it is the correct device and check the SDK EVO / LK EVO /KS EVO connections.
Update the FW (see procedure
72
).
If the problem persists, replace the SDK EVO /LK EVO /KS EVO .
62
62
Battery charger
failure
Perform RESET.
If the problem persists, replace the board.
63
63
Intrusion in progress
An attempt to manually open the leaves is in progress
65
65
SETUP in progress
SETUP is in progress.
67
67
Battery saving
Power to the accessories of the board (Excluding the SDK-EVO) has been disconnected to
save the battery and prevent it from discharging rapidly.
68
68
Safeties test failed
Check that the safety detector is working
If the problem persists, replace the detector.
In this condition the leaves move at a slower speed.
69
69
Door open
the door is open for semi-automatic OPEN function.
70
70
Low batteries level
batteries discharged
71
71
Intermode Slave
board configured as Slave and the operating mode is that of the Master.
72
72
Intermode node registration
Wait for the procedure to finish
73
73
Intermode Node Alarm
Master : At least one node does not respond / Slave : The Master does not communicate.
74
74
INTERLOCK
INTERLOCK operating mode active.
80
80
Non-Standard
Non Standard configuration in use.
16
Warnings
Содержание A1000
Страница 1: ...A1000 EN16005 2012 E1SL fw 3 0 SDK EVO fw 3 0 LK EVO fw 1 2...
Страница 108: ...A1000 108 53221004 Rev A Translation of the original instructions ENGLISH...
Страница 110: ...A1000 110 53221004 Rev A...
Страница 114: ...A1000 114 53221004 Rev A...
Страница 115: ...Translation of the original instructions ENGLISH...