![F.W. Bell 7030 Скачать руководство пользователя страница 94](http://html.mh-extra.com/html/f-w-bell/7030/7030_instruction-manual_535140094.webp)
F.W. BELL Model 7030 Gauss/Tesla Meter Instruction Manual
7-20
Section 7 – Remote Operation
Table 7-4c SCPI Status Register Commands
COMMAND DESCRIPTION
:STATus:MEASurement:EVENt? Query the Measurement Event reg.
:STATus:OPERation:EVENt? Query the Operation Event reg.
:STATus:QUEStionable:EVENt? Query
the Questionable Event reg.
:STATus:MEASurement:ENABle <NRf>
Set the Measurement Event Enable reg.
:STATus:OPERation:ENABle <NRf>
Set the Operation Event Enable reg.
:STATus:QUEStionable:ENABle <NRf>
Set the Questionable Event Enable reg.
:STATus:MEASurement:ENABle? Query
the Measurement Event Enable reg.
:STATus:OPERation:ENABle? Query
the Operation Event Enable reg.
:STATus:QUEStionable:ENABle? Query
the Questionable Event Enable reg.
:STATus:MEASurement:CONDition? Query the Measurement Condition reg.
:STATus:OPERation:CONDition? Query the Operation Condition reg.
:STATus:QUEStionable:CONDition? Query the Questionable Condition reg.
:STATus:PRESet
Clear all event registers.
Table 7-4d SCPI Unit Commands
COMMAND
DESCRIPTION
:UNIT:ANGLe DEG|RAD
Define the vector summation angular units
:UNIT:ANGLe?
Query the vector summation angular units
:UNIT:TEMPerature C|CEL|F|FAR|K
Define the temperature units
:UNIT:TEMPerature?
Query the temperature units
:UNIT:FLUX GAUSs|TESLa|AM|OERSted
Define the flux density units
:UNIT:FLUX?
Query the flux density units
:UNIT:TIMe SEC|HZ
Define the time-based measurement units
:UNIT:TIMe?
Query the time-based measurement units
Table 7-4e SCPI Range Commands
COMMAND
DESCRIPTION
:SENSe#:FLUX:DC
Set a channel for dc flux density
:SENSe#:FLUX:AC
Set a channel for ac flux density
:SENSe#:FLUX:RANGe:AUTo <b>
Enable/disable auto range in dc mode
:SENSe#:FLUX:DC:RANGe:AUTo <b>
Enable/disable auto range in dc mode
:SENSe#:FLUX:AC:RANGe:AUTo <b>
Enable/disable auto range in ac mode
:SENSe#:FLUX:RANGe:FIXed <n>
Define a fixed range in dc mode
:SENSe#:FLUX:DC:RANGe:FIXed <n>
Define a fixed range in dc mode
:SENSe#:FLUX:AC:RANGe:FIXed <n>
Define a fixed range in ac mode
:SENSe#:FLUX:RANGe?
Query range and ac/dc setting
Table 7-4f SCPI Filter Commands
COMMAND DESCRIPTION
:SENSe#:FLUX:FILTer:LPASs:STATe <b>
Turn on low-pass filter
:SENSe#:FLUX:FILTer:LPASs:STATe? Query
on/off state of the low-pass filter
:SENSe#:FLUX:FILTer:LPASs:
FREQuency <NRf>
Define the low-pass filter cutoff frequency
:SENSe#:FLUX:FILTer:LPASs:
FREQuency?
Query the low-pass filter cutoff frequency
Содержание 7030
Страница 1: ...7030 GAUSS TESLA METER Instruction Manual ...
Страница 2: ...F W BELL Model 7030 Gauss Tesla Meter Instruction Manual THIS SIDE BLANK Inside of Front Cover ...
Страница 24: ......
Страница 25: ...THIS SIDE BLANK Rear of page 2 7 ...
Страница 26: ......
Страница 38: ...F W BELL Model 7030 Gauss Tesla Meter Instruction Manual 4 8 Section 4 Setup This Page Intentionally Blank ...
Страница 122: ...THIS SIDE BLANK Back B 3 ...
Страница 124: ...THIS SIDE BLANK Back of Warranty ...
Страница 125: ...THIS SIDE BLANK Inside of Rear Cover ...
Страница 126: ...4607 SE International Way Milwaukie OR 97222 Phone 503 659 5999 www oeco com ...