![F.W. Bell 7030 Скачать руководство пользователя страница 90](http://html.mh-extra.com/html/f-w-bell/7030/7030_instruction-manual_535140090.webp)
F.W. BELL Model 7030 Gauss/Tesla Meter Instruction Manual
7-16
Section 7 – Remote Operation
IEEE-488.2
“COMMON”
COMMANDS
(Continued)
*ESR? - STANDARD EVENT REGISTER QUERY
Read the contents of the STANDARD EVENT register. The results are placed
in the output queue of the instrument.
NOTE: The STANDARD EVENT register is cleared after an *ESR? command.
*IDN? - IDENTIFICATION QUERY
Returns the following string:
F.W.BELL,7030 GAUSS-TESLAMETER,Vx.x
.
The Vx.x string is the firmware revision level, where x.x is a decimal number,
such as 1.1.
*OPC - SET OPERATION COMPLETE
Causes the OPC (operation complete) bit to set in the STANDARD EVENT
register when all commands have been executed.
*OPC? - OPERATION COMPLETE QUERY
Places an ASCII “1” in the output queue once all commands have been
executed. This is particularly useful when using the RS-232 Port.
*OPT? - OPTION IDENTIFICATION QUERY
Indicates the existence and identity of all attached Hall probes.
Two numbers will be returned for Channel-1’s probe, separated by a comma (,).
The first number is the model number of the probe and can be up to 12
characters in length, such as STF71060815T. If the probe is missing, a “0” will
be returned. The second number is the probe’s serial number and can be up to
10 characters in length, such as 9923009. If the probe is missing, a “0” will be
returned.
This sequence is repeated for Channel-2 and -3. All strings are separated by
commas (,). For instance, if only Channel-2’s probe is attached, the returned
string will be:
0,0,STF71060815T,9923009,0,0
*RCL <n> - RECALL SETUP
The present state of the instrument, called the setup, can be saved in non-
volatile memory and later recalled with this command to instantly return the
instrument to that state. Up to four different setups can be saved. <n> should
be a single ASCII character from “1” to “4” to specify the memory location. If
<n> is omitted then “1” is assumed.
For more information see the discussion about the SYSTEM menu.
Содержание 7030
Страница 1: ...7030 GAUSS TESLA METER Instruction Manual ...
Страница 2: ...F W BELL Model 7030 Gauss Tesla Meter Instruction Manual THIS SIDE BLANK Inside of Front Cover ...
Страница 24: ......
Страница 25: ...THIS SIDE BLANK Rear of page 2 7 ...
Страница 26: ......
Страница 38: ...F W BELL Model 7030 Gauss Tesla Meter Instruction Manual 4 8 Section 4 Setup This Page Intentionally Blank ...
Страница 122: ...THIS SIDE BLANK Back B 3 ...
Страница 124: ...THIS SIDE BLANK Back of Warranty ...
Страница 125: ...THIS SIDE BLANK Inside of Rear Cover ...
Страница 126: ...4607 SE International Way Milwaukie OR 97222 Phone 503 659 5999 www oeco com ...