Page | 49
14.2.
INSTALLATION PREPARATION
14.2.1.
Interlock electrical connections are shown in FIG. 14.5 and FIG. 14.6.
14.2.2.
Strip the 18/4 SOOW cord insulation back, exposing approximately 1.25” of internal 4
-
white, black, green, and red wires (FIG. 14.5).
14.2.3.
Strip the insulator from the internal white, black, green, and red wires to expose 1/2” of
the conductor (FIG. 14.7).
14.2.4.
Remove the cover from the interlock and connect the wires from the SOOW cord as shown
(FIG. 14.5).
14.2.5.
Cut wire, if needed, to lengths shown below:
LIFT HEIGHT
CUT LENGTH
44”
Cut 85” wire to 57”
52”
Cut 85” wire to 65”
72”
Do NOT cut; leave wire at
85”
120”
Cut 181” wire to 133”
144”
Cut 181” wire to 133”
168”
Do NOT cut; leave wire at
181”
14.2.6.
Strip the end of red 16-gauge wire to expose 1/4" of conductor.
14.2.7.
Insert stripped end of red 16-gauge wire into open end of butt connector on inline fuse
holder wire (FIG. 14.9).
Make sure conductor is fully engaged with metal tube inside butt connector.
14.2.8.
Crimp metal tube section tight with wire crimper. Gently tug on wire to ensure tight fit.
14.2.8.1.
Heat the end of butt connector to shrink for water-tight fit.
TERMINAL 1 = UNUSED
TERMINAL 2 = UNUSED
TERMINAL 3 = WHITE
TERMINAL 4 = BLACK
TERMINAL 5 = GREEN
TERMINAL 6 = RED
A = WHITE
B = GREEN
C = BLACK
D = RED
FIG. 14.5
FIG. 14.6
FIG. 14.7
1.25”