Page | 67
24.
WRITTEN MAINTENANCE PROGRAM (WMP) AND SERVICE LOG FOR THE
EZ-ACCESS PASSPORT® VERTICAL PLATFORM LIFT
24.1
ROUTINE MAINTENANCE AND INSPECTION/TEST SCHEDULE: Refer to the PASSPORT® Vertical Platform
Lift (VPL) User manual, Installation Manual, and all applicable supplements and addendums, if any.
Attention maintenance/service personnel
–
action required!
Maintenance/service personnel are required to document maintenance and service activities
(photocopy the pages as needed). The WMP and Service Log must be immediately available to any
inspector, maintenance, or service personnel at the site of the VPL installation. Service Logs must be
kept for a period of 5-years.
The WMP and Service Logs belong to the VPL owner. DO NOT remove from the VPL installation site.
Additional documentation required to remain on-site:
(a) Wiring Diagram, (b) Installation Manual, (c) User Manual, (d) Service Log
In case of a non-life threatening VPL-related emergency, contact your dealer or EZ ACCESS Technical
Support at 1-800-332-1381.
All maintenance and service must be performed only by EZ-ACCESS approved technicians. Contact
your dealer with questions.
LUBRICATE HI-LEAD® SCREW*
EVERY 6 MONTHS
INSPECT/CONFIRM LABELS ARE PRESENT AND LEGIBLE
ROUTINE INSPECTIONS & TEST ANNUALLY
TEST/CONFIRM CORDED CONTROLS OPERATE LIFT AS BUTTONS INDICATE: UP, DOWN, EMERGENCY STOP
ROUTINE INSPECTIONS & TEST ANNUALLY
TEST REMOTE CONTROLS: CONFIRM VPL OPERATES AS BUTTONS INDICATE: UP, DOWN
ROUTINE INSPECTIONS & TEST ANNUALLY
TEST/CONFIRM KEYED POWER SWITCH FUNCTIONS
ROUTINE INSPECTIONS & TEST ANNUALLY
TEST/CONFIRM PLATFORM STOPS AT UPPER LANDING
ROUTINE INSPECTIONS & TEST ANNUALLY
INSPECT/CONFIRM AC POWER CORD IS UNDAMAGED
ROUTINE INSPECTIONS & TEST ANNUALLY
IF EQUIPPED: TEST/CONFIRM UPPER LANDING GATE LATCHING MECHANISM FUNCTIONS PROPERLY
ROUTINE INSPECTIONS & TEST ANNUALLY
IF EQUIPPED: TEST/CONFIRM PROPER OPERATION OF INTERLOCK
ROUTINE INSPECTIONS & TEST ANNUALLY
IF EQUIPPED: TEST/CONFIRM PROPER OPERATION CALL/SEND CONTROL(S)
ROUTINE INSPECTIONS & TEST ANNUALLY
IF EQUIPPED: TEST/CONFIRM PROPER OPERATION OF PLATFORM GATE
ROUTINE INSPECTIONS & TEST ANNUALLY
VISUALLY INSPECT ALL ELECTRICAL CONNECTIONS FOR CORROSION OR DAMAGE
ROUTINE INSPECTIONS & TEST ANNUALLY
VISUALLY INSPECT FOR MISSING OR DAMAGED HARDWARE
ROUTINE INSPECTIONS & TEST ANNUALLY
ENSURE GUARD WALLS ARE MOUNTED SECURELY
ROUTINE INSPECTIONS & TEST ANNUALLY
ENSURE GUARD RAMP OPENS AND CLOSES FREELY
ROUTINE INSPECTIONS & TEST ANNUALLY
VISUALLY INSPECT RUB STRIPS FOR SIGNS OF WEAR
ROUTINE INSPECTIONS & TEST ANNUALLY
VISUALLY INSPECT LUBRICATE HI-LEAD® SCREW
ROUTINE INSPECTIONS & TEST ANNUALLY
TEST SAFETY PAN TO ENSURE PROPER FUNCTION
ROUTINE INSPECTIONS & TEST ANNUALLY
*
CERTAIN ENVIRONMENTAL FACTORS MAY REQUIRE MORE FREQUENT SERVICE INTERVALS
Содержание Passport PL44SP3651
Страница 27: ...Page 27 FIG 9 1 FIG 9 2 ...
Страница 65: ...Page 65 23 ELECTRICAL DRAWING ...