Page | 39
10.3.
INSTALLATION TO PATHWAY® 3G
10.3.1.
The PATHWAY® 3G connector kit, also known as a closure kit, includes two 1-
1/2” diameter
handrail tubes, two connector plates, two clamp plates, two 5/16”
-18 threaded round tube
inserts, and attachment hardware (FIG. 10.4). If connecting both gate posts to platform
handrail posts, use two kits.
The 1-
1/2” diameter handrail tubes are sized for larger (6’) platforms and are typically
cut to fit others.
10.3.2.
Install the PATHWAY platform (per PATHWAY instructions) in the desired location.
10.3.2.1.
Do not install a handrail on the side of the platform where the gate will be
installed.
10.3.3.
A smooth fascia panel is required to fill the area underneath the gate, between the platform
and the ground.
It is the installer’s responsibility to construct this fascia and confirm it meets applicable
building codes.
FIG. 10.4
10.3.4.
Install Top Landing Gate per instructions in SECTION 9.
10.3.5.
Assemble one of the handrail tubes to a connector plate using two #10 x 1” long self
-
tapping hex washer head screws.
10.3.6.
Hold the connector plate with handrail tube against the outside of the gate post where it
will be attached and mark the handrail tube at the location flush with the platform
handrail post.
10.3.6.1.
Subtract the thickness of the
5/16”
-18 threaded round tube insert.
10.3.6.2.
Mark the tube for cutting.
10.3.7.
Cut both tubes to the length determined in the previous steps.
10.3.8.
If they were disassembled for cutting, reassemble the connector plate to the handrail
tube and assemble the clamp plate to the connector plate using two 5/16”
-
18 x 3/4” long
button head socket clamp screws through the larger holes in the connector plate and
into the tapped holes in the clamp plate.
10.3.8.1.
Do not tighten fully at this time.