14.3.11.
Connect the male spade connector on the end of the 16” black wire with the 1/4” ring
terminal on the opposite end to the female spade connector on the blue wire, which was
disconnected in the previous step. (FIG. 14.14).
14.3.12.
Remove 1/4” nut & bolt attaching
purple ground wire to upper left gusset on carriage. Slide
1/4” ring terminal on other end of 16” black wire over bolt and reassemble so both purple
and black wires are grounded to carriage (FIG. 14.15).
14.3.13.
Secure the added wires to existing wires with the zip ties provided. Cut excess material from
zip ties as needed (FIG. 14.16).
14.3.14.
Reinstall the front and rear cover panels on lift tower.
14.3.15.
Reinstall the rear platform guard wall.
14.3.16.
Follow the Porta Electric EMDL 06 Door Interlock manufacturer’s instructions for the
mounting and use of the Interlock on an existing door.
14.3.17.
Reattach the white 10-gauge ground wire to negative battery terminal.
14.3.18.
Reinstall the plastic cover on power head.
14.3.19.
Plug in AC power cord and turn the VPL keyed power switch to the “ON” position.
14.3.20.
Test exterior door interlock
14.3.21.
With door closed, operate lift through entire range of travel up and down. The door interlock
mechanism should only unlatch and allow door to open when lift platform is within 3” of
threshold. The door must also be closed and interlock latched for the platform to descend
more than 3” from the threshold.
VPLs altered to operate with an interlock will not operate correctly if connected to a
top landing gate. The wiring must be returned to its original wiring scheme (pre-
interlock alteration) to work with the top landing gate.