![Exlar Tritex Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/exlar/tritex/tritex_installation-manual_2450859022.webp)
Tritex 1 Installation and Setup
22
09/27/12
PN: 27666
Exlar Corporation
Rev. M
952-500-6200M
RTM/RTG Series
TRITEX RTM/G SERIES ORDERING GUIDE
AAABBB-CCC-DE-FFF-FF- (XX…XX) - #####
AAA = Actuator Type
E = Connector Options
RTM = Tritex Rotary Motor
I = Exlar Std M23 style connector
B = Embedded Leads
RTG = Tritex Rotary Gearmotor
P = Embedded leads w/plug
X = Special (please specify)
BBB = Frame Size
FFF-FF = Motor Stators
060 = 60 mm
RTM/RTG060
090 = 90 mm
1B8-50 = 1 Stack, 5000 rpm at 48 VDC, 2500 rpm at 24 VDC
CCC = Gear Ratio
2B8-34 = 2 Stack, 3400 rpm at 48 VDC, 1700 rpm at 24 VDC
Blank = RTM
3B8-25 = 3 Stack, 2500 rpm at 48 VDC, 1250 rpm at 24 VDC
Single Reduction Ratios
Double Reduction Ratios
RTM/RTG090
004 = 4:1
016 = 16:1
1B8-17 = 1 Stack, 1700 rpm at 48 VDC, 850 VDC at 24 VDC
005 = 5:1
020 = 20:1
2B8-10 = 2 Stack, 1000 rpm at 48 VDC, 500 VDC at 24 VDC
010 = 10:1
025 = 25:1
3B8-07 = 3 Stack, 700 rpm at 48 VDC, 350 VDC at 24 VDC
040 = 40:1
XX = Special Options
050 = 50:1
XH = Special Housing Options
100 = 100:1
XM = Special Motor Options
D = Shaft Type
XL = Special Lubrication
K = Keyed, R = Smooth/Round, X = Special Shaft
##### = 5 digit PN assigned to designate special model
number
Optional 5 digit assigned PN to designate unique model number
RSM/RSG Series, Also see TRA500 page 22
REMOTE TRITEX RSM/RSG SERIES ORDERING GUIDE
AAABBB-CCC-DE-FFF-FF- (XX…XX) - #####
AAA = Actuator Type
E = Connector Options
RSM = Tritex Rotary Motor Used with TRA500 remote drive
I = Exlar Std M23 style connector
RSG = Tritex Rotary Gearmotor Used with TRA500 remote
drive
P = Embedded leads w/plug
BBB = Frame Size
FFF-FF = Motor Stators
060 = 60 mm
RSM/RSG060
090 = 90 mm
1B8-50 = 1 Stack, 5000 rpm at 48 VDC, 2500 rpm at 24 VDC
CCC = Gear Ratio
2B8-34 = 2 Stack, 3400 rpm at 48 VDC, 1700 rpm at 24 VDC
Blank = RTM
3B8-25 = 3 Stack, 2500 rpm at 48 VDC, 1250 rpm at 24 VDC
Single Reduction Ratios
Double Reduction Ratios
RSM/RSG090
004 = 4:1
016 = 16:1
1B8-17 = 1 Stack, 1700 rpm at 48 VDC, 850 VDC at 24 VDC
005 = 5:1
020 = 20:1
2B8-10 = 2 Stack, 1000 rpm at 48 VDC, 500 VDC at 24 VDC
010 = 10:1
025 = 25:1
3B8-07 = 3 Stack, 700 rpm at 48 VDC, 350 VDC at 24 VDC
040 = 40:1
XX = Special Options
050 = 50:1
XH = Special Housing Options
100 = 100:1
XM = Special Motor Options
D = Shaft Type
XL = Special Lubrication
K = Keyed, R = Smooth/Round, X = Special Shaft
##### = 5 digit PN assigned to designate special model
number
Optional 5 digit assigned PN to designate unique model number
Содержание Tritex
Страница 27: ...Tritex 1 Installation and Setup 27 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TLM20 Dimensions...
Страница 28: ...Tritex 1 Installation and Setup 28 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TSM20 Dimensions...
Страница 29: ...Tritex 1 Installation and Setup 29 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TLM30 Dimensions...
Страница 30: ...Tritex 1 Installation and Setup 30 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TSM30 Dimensions...
Страница 122: ...Tritex 1 Installation and Setup 122 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TTPS1048 Dimensions...
Страница 125: ...Tritex 1 Installation and Setup 125 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M T232485 Schematic...
Страница 132: ...Tritex 1 Installation and Setup 132 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TTSR1 Dimensions...
Страница 134: ...Tritex 1 Installation and Setup 134 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M Declaration of Conformity...