Tritex 1 Installation and Setup
111
09/27/12
PN: 27666
Exlar Corporation
Rev. M
952-500-6200M
when the Actual Current is equal to or greater than this value. You should set the appropriate
Current Limit above the current required to move the actuator at the home speed, but below the
rated current of the actuator.
Termination:
This action will end the Home move and define the actual home position as
entered in the
Home Position
parameter.
Home towards valve open direction
: Select this box to home to the open valve position. The
Home Position should be equal to the Open Valve position found on the Valve Configuration
page.
Auto Home on Enable
: Select if a Home operation if automatically performed on power-up.
Require Home before analog positioning operation
: If checked requires a Home to be completed
before operation from the analog signal
.
Require Home before digital I/O operation
: If checked requires a Home to be completed before
operation from the digital I/O operation.
Jog Operation
Jog Page
Jog Parameters
Jog Slow:
The Jog speed when
the Fast Jog is not selected
Jog Fast: The Jog speed when
the Fast Jog is selected
Jog Acceleration
: The
Acceleration and Deceleration
ramp used in Jog Mode
Jog Controls
Jog Fast, Slow and
Acceleration slider bars provide
easy change of jog parameters
that take effect immediately but
are not save permanently
unless a download is
performed. The Jog (+) an d
Jog (-) buttons will activate a
Jog as long as they held down
with a mouse click. The
indicators next to buttons
illuminate when the Jog is
active.
Jog Fast Check Box or Input
Functions selects the Jog Fast
velocity.
Содержание Tritex
Страница 27: ...Tritex 1 Installation and Setup 27 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TLM20 Dimensions...
Страница 28: ...Tritex 1 Installation and Setup 28 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TSM20 Dimensions...
Страница 29: ...Tritex 1 Installation and Setup 29 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TLM30 Dimensions...
Страница 30: ...Tritex 1 Installation and Setup 30 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TSM30 Dimensions...
Страница 122: ...Tritex 1 Installation and Setup 122 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TTPS1048 Dimensions...
Страница 125: ...Tritex 1 Installation and Setup 125 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M T232485 Schematic...
Страница 132: ...Tritex 1 Installation and Setup 132 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TTSR1 Dimensions...
Страница 134: ...Tritex 1 Installation and Setup 134 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M Declaration of Conformity...