Tritex 1 Installation and Setup
101
09/27/12
PN: 27666
Exlar Corporation
Rev. M
952-500-6200M
Online Diagnostics
Tuning
Tritex default gains are set to work out of the box for many applications, for those applications
that require tuning two parameters are provided on the Tuning page.
Tuning Adjustments
The drive’s proprietary motion controls algorithms have been designed to reduce the number of
tuning parameters for the customer. There are only 2 parameters; Position and Speed Stiffness.
If the drive is online changes to the gain parameters take effect immediately, however they will
not be save in non volatile memory until a down load is performed.
Positional Stiffness
: Determines how tightly position is tracked, both during motion and at a
stop. Too high of a setting can cause instability and overshooting of position. Too low of a
setting will cause sluggish motion. For systems with backlash or compliance the Positional
Stiffness will need to be lower.
Speed Stiffness
: Determines how tightly the velocity profile is followed during a move. It has no
affect at zero velocity. Too high of a setting can cause erratic motion at low speed. Systems
with higher friction loads or high constant force loads usually require the speed stiffness to be
turned up, so the move profile is more closely followed, if the speed falls behind during the
move, the excess following error can cause overshoot at the end of the move.
Содержание Tritex
Страница 27: ...Tritex 1 Installation and Setup 27 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TLM20 Dimensions...
Страница 28: ...Tritex 1 Installation and Setup 28 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TSM20 Dimensions...
Страница 29: ...Tritex 1 Installation and Setup 29 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TLM30 Dimensions...
Страница 30: ...Tritex 1 Installation and Setup 30 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TSM30 Dimensions...
Страница 122: ...Tritex 1 Installation and Setup 122 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TTPS1048 Dimensions...
Страница 125: ...Tritex 1 Installation and Setup 125 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M T232485 Schematic...
Страница 132: ...Tritex 1 Installation and Setup 132 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TTSR1 Dimensions...
Страница 134: ...Tritex 1 Installation and Setup 134 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M Declaration of Conformity...