EFT/B & Surge Filter
37263 EFT/B & Surge Filter Introduction
Electrical Fast Transient/Burst (EFT/B) and Surge disturbances are caused by a number of
events including switching inductive loads, relay contact bounce, power system switching
activity or faults, nearby lightning strikes, etc. The effect of these disturbances can range from
temporary service interruption to permanent failure of equipment that is not sufficiently
protected.
37263 EFT/B & Surge Filter Features
-
Designed for use with Tritex Linear and Rotary Actuators
-
Place in series with power cable as close as possible to disturbance source
-
Provides EFT/B and Surge disturbance immunity to IEC/EN 61800-3:2004-08 Second
Environment (Industrial) levels
-
35mm top hat DIN rail mountable using Wago 209-188 mounting feet (not provided)
37263 EFT/B & Surge Filter Specifications
Voltage:
150V Maximum
Current:
15A Maximum
Temperature Range:
-40 to 85°C
Size (L x W x H):
3.4” x 1.8” x 0.8”
Weight:
50 g Maximum
Connections:
12-30 AWG Input (LINE) and Output (LOAD) Terminal Block
Connections for Bus Power (BUS), Logic Power (LGC), Power
Common (RTN), and PE
37263 EFT/B & Surge Filter Dimensions
Содержание Tritex
Страница 27: ...Tritex 1 Installation and Setup 27 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TLM20 Dimensions...
Страница 28: ...Tritex 1 Installation and Setup 28 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TSM20 Dimensions...
Страница 29: ...Tritex 1 Installation and Setup 29 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TLM30 Dimensions...
Страница 30: ...Tritex 1 Installation and Setup 30 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TSM30 Dimensions...
Страница 122: ...Tritex 1 Installation and Setup 122 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TTPS1048 Dimensions...
Страница 125: ...Tritex 1 Installation and Setup 125 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M T232485 Schematic...
Страница 132: ...Tritex 1 Installation and Setup 132 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M TTSR1 Dimensions...
Страница 134: ...Tritex 1 Installation and Setup 134 09 27 12 PN 27666 Exlar Corporation Rev M 952 500 6200M Declaration of Conformity...