35
DEPOLOX® 5 E flow cell
4. Installation
EN
13 Install the SiDiSens LF module on the left
side in the flow cell and secure with the
enclosed plastic self-tapping screws
(W2T807965 - 10 mm) in item A (Fig. 18)
(mounting recess).
Fig. 17 Cutout of flow cell
14 Plug in the CAN sensor cable of the SiDi-
Sens LF module (Fig. 18 - item C). The
M12 terminating resistor must be scre-
wed on CAN socket (Fig. 19 - item C).
15 The membrane sensor is connected either
at the CAN socket (Fig. 19 - item C) on
conductivity module SiDiSens connected
directly via the CAN extension socket (Fig.
18 - item C) on DFMe electronics module.
16 Refit and engage the housing cover of the
flow cell.
17 Switch the power supply on again.
Fig. 18 DEPOLOX® 5 E flow cell, non-
pressurized
A Mounting recess
B
CAN sensor cable connection
C
SiDiSens LF connection
D Membrane sensor connection
ATTENTION
Damage to flow cell!
The screws should not be confused.
Distinguish between the plastic self-tapping
screws for installing the flow cell and those
used for the SiDiSens module.
Prior to the installation of the SiDiSens
module, ensure that you use the correct
plastic self-tapping screws. Use only the
plastic self-tapping screws A2 (W2T807965 -
10 mm) when installing the SiDiSens
module.
Plastic self-tapping
screw (10 mm)
NOTICE
The pressurized version can be retrofitted
with the total chlorine membrane sensor
TC3 CAN (chapter 4.21.2).
B
D
A
C