EN
Sample water extraction, drawing on page 26
•
for fresh water (W3T158528)
•
for salt water (W3T158529)
4.11 Installing the fine filter
1 Release both knurled nuts (B).
2 Remove the complete filter unit (A).
3 Push the fine filter (D) into the filter unit.
Ensure that the O-ring (C) is fitted cor-
rectly.
4 Fit the complete filter unit (A). Ensure
that it is in the correct position (top/bot-
tom).
5 Tighten the knurled nuts (B).
Fig. 5
Detail: Fow cell
Fig. 6
Filter unit cross-section
A Entire filter unit
B
Knurled nut
C
O-ring
D Fine filter
Item Qty.
Part No.
Designation
2
1
W2T505181 Screw joint
3
2
W2T505182 Screw joint
4
1
W3T171416 Strainer complete
6
1
W3T167518 Hose connection parts
7
1
W3T173160
W3T173198
Pressure gage:
•
fresh water
•
salt water
9
1
W2T505945 Ball valve
11
1
W3T163670 Sample pipe
14
1
W3T172948 Threaded part
17
1
W2T505600 Reduction
20
1
W3T163500 Reduction nipple
23
1
W2T507288 Insert
24
1
W2T506934 Union nut
25
1
W3T172720 O-ring
26
1
W3T161254 Flat gasket
27
1
W3T171146 Nozzle washer
28
1
W3T172727 Flat gasket
35
1
W3T166090 Pipe segment
36
2
W2T506782 Reducing junction, short
39
1
W2T506527 T-piece
40
1
W3T166089 Pipe segment
41
1
W2T506778 Reducing junction, short
42
1
W2T507525 T-piece
43
1
W2T507535 Elbow bend
NOTICE
A fine filter must only be installed when
membrane sensors are employed.
A
B
C
D
B
bottom
top