18
4. Installation
DEPOLOX® 5 E flow cell
EN
4.
Installation
4.1
Scope of supply
The DEPOLOX® 5 E flow cell (module type D01)
can be comined with 700 P electronics module
(module type E01) or 700 M electronics
module (module type E01). Depending on the
individual order, the scope of supply includes
the following:
•
Pool Management System DEPOLOX® 5 E
700 P
•
Measuring and control unit DEPOLOX® 5 E
700 M
4.1.1 Pool Management System
DEPOLOX® 5 E 700 P
The scope of delivery of the DEPOLOX® 5 E
flow cell inclu®es the following:
•
DEPOLOX®
5 E flow cell (module type D01)
with 3-electrode measuring cell for free
chlorine (chlorine dioxide or ozone)
•
Non-pressurized or pressurized ver-
sion
•
LED glow stick
•
Top-hat rail
•
Assembly accessories
•
Instruction manual
4.1.2 Measuring and control unit
DEPOLOX® 5 E 700 M
The scope of supply of the measuring and con-
trol unit DEPOLOX® 5 E 700 M includes the fol-
lowing, depending on the order:
•
DEPOLOX®
5 E flow cell (module type D01)
with 3-electrode measuring cell for free
chlorine (chlorine dioxide or ozone)
•
Non-pressurized version or
pressurized version
•
700 M electronics module (module type
E01)
•
With 4-way mA output card
•
8x relay outputs
•
LED glow stick
•
Top-hat rail
•
Assembly accessories
•
Instruction manual DEPOLOX®
5 E flow
cell, German/Englisch
•
Instruction manual 700 M electronics
module, German/Englisch
4.2
Transport and storage
Transport
The flow cell is supplied in standard packaging.
During transport, the packaged system must
be handled carefully and should not be expo-
sed to wet weather or moisture.
Check that the transport packaging is unda-
maged. In the event of damage, please inform
the transport company immediately, as your
rights to compensation will otherwise be lost.
If a component is damaged, please contact
your affiliate immediately.
Keep the packaging until the flow cell has been
correctly installed and taken into operation.
Storage
Store the electronics module, the flow cell and
the sensors in a dry condition without any resi-
dual water in a dry place that is not exposed to
the weather. .
Shut-down
The flow cell may only be taken out of opera-
tion by trained and authorized personnel.
NOTICE
The DEPOLOX® 5 E flow cell is factory-confi-
gured according to the customer’s specific
requirements with the 700 P electronics
module according to the variant code (chap-
ter 3.1.1).
NOTICE
The scope of supply mainly differs in the ver-
sions of the DEPOLOX® 5 E flow cell (non-
pressurized or pressurized) as well as the
sensors.
ATTENTION
Damage to device and sensor!
Observe different storage temperatures
(chapter 3.7) and manufacturer specifica-
tions of the buffer solution and calibration
solution.