10
3. Description
DEPOLOX® 5 E flow cell
EN
3.1.2 Measuring and control unit
DEPOLOX
®
5 E 700 M
The measuring and control unit DEPOLOX®
5 E
700 M is available in various versions. They
mainly differ in the versions of the DEPOLOX®
5 E flow cell (module type D01) (non-pressuri-
zed or pressurized) as well as the sensors. The
measuring and control unit DEPOLOX® 5 E 700
M consists of the following:
•
700 M electronics module (module type
E01)
•
DEPOLOX® 5 E flow cell (module type
D01) with 3-electrode measuring cell for
free chlorine (chlorine dioxide or ozone)
•
Non-pressurized version or
pressurized version
•
LED glow stick
•
4-way mA output card
•
Eight relay outputs
Optional:
•
pH reference electrode
•
Redox reference electrode
•
Membrane sensor for total chlorine TC3
CAN
•
Conductivity sensor
DEPOLOX® 5 E 700 M - Non-pressurized version
Part no.
electr
o
d
e measu
ring ce
ll f
o
r fr
e
e ch
lor
in
e
(c
h
lorin
e dio
xid
e o
r o
zon
e)
pH
r
ef
e
re
n
ce electr
o
d
e
R
e
d
o
x ref
ere
n
ce
e
le
ctrod
e
Membr
ane sensor f
o
r
tota
l ch
lo
ri
ne
T
C
3
CA
N
Conduc
tivity sensor
W3T371112
X
W3T371113
X
X
W3T371114
X
X
X
W3T371115
X
X
X
X
W3T371116
X
X
X
X
X
DEPOLOX® 5 E 700 M - Pressurized version
Part no.
e
lectr
o
d
e measur
in
g ce
ll f
o
r
fr
e
e ch
lorin
e
(c
hl
orine dio
xide o
r
o
zone)
pH
r
ef
er
en
ce
electr
o
d
e
R
e
d
o
x ref
ere
n
ce
e
le
ct
rod
e
Membr
ane sensor f
o
r
tota
l c
h
lo
ri
ne
T
C
3
C
A
N
C
o
nd
uc
tivity s
e
n
sor
W3T370967
X
W3T370968
X
X
W3T370969
X
X
X
W3T370970
X
X
X
X
NOTICE
The pressurized version can be retrofitted
with the total chlorine membrane sensor TC3
CAN. Please note that the standard cell body
cover must be replaced by an optional cell
body cover, part no. W3T417351.