28
4. Installation
DEPOLOX® 5 E flow cell
EN
4.12 Removing the felt ring
To keep the diaphragm moist and prevent
crystallization in the electrolyte solution there
is a moist felt washer in the gap between elec-
trolyte tank and electrode when the unit is in
storage.
1 Extract the knurled nut (A) from the cover
of the electrolyte tank.
2 Remove the entire electrode unit from
the cell body from below.
3 Remove the felt washer (B) between elec-
trolyte tank and electrode.
4 Refit the entire electrode unit in the cell
body. With the locating pin, observe the
exact position in the cell body.
5 Push the entire electrode unit upwards.
6 Refit the knurled nut on the electrolyte
tank.
Fig. 7
Cross-section of cell body, non-pres-
surized version (example knurled nut)
A Knurled nut
B
Felt washer
4.13 Removing and replacing trans-
port caps
4.13.1 Non-pressurized version
1 Take out the yellow protection cap of the
electrolyte tank.
2 Replace the transport cap with the enclo-
sed operating cap.
Fig. 8
Detail: cell body cover, non-
pressurized version
A Protection cap (yellow)
B
Stopper (with white venting rod)
ATTENTION
Before initial startup, the felt washer for
moistening the membranes must be remo-
ved.
A
B
ATTENTION
Before initial commissioning of the
DEPOLOX® 5 E, the transport cap of the elec-
trolyte tank must be removed and replaced
with the enclosed operating cap.
A
B