6-24
Programming Your Application
605 Series Frequency Inverter
DIGITAL OUTPUT
The digital output block converts a logic TRUE or FALSE demand to a physical output signal.
Functional Description
The inverter has two physical digital outputs. There is a DIGITAL OUTPUT function block
associated with each of these:
DIGITAL OUTPUT 1 is associated with terminal 13
DIGITAL OUTPUT 2 is associated with terminal 14
INVERT reverses the output logic.
MMI Menu Map
1
SETUP PARAMETERS
2
FUNCTION BLOCKS
3
INPUTS & OUTPUTS
4
DIGITAL OUTPUT
5
DIGITAL OUTPUT
1
5
DIGITAL OUTPUT
2
DOUT 2 VALUE
DOUT 2 INVERT
Parameter Descriptions
VALUE
Range: FALSE / TRUE
The TRUE or FALSE output demand.
INVERT
Range: FALSE / TRUE
Controls the optional inversion of the VALUE output.
DIGITAL OUTPUT 2
FALSE – [ 55]
VALUE
–
FALSE
–
[ 54]
INVERT
–
DIGITAL OUTPUT 1
FALSE – [ 52]
VALUE
–
FALSE
–
[ 51]
INVERT
–
OUTPUT
INVERT
VALUE
Содержание 605 Series
Страница 16: ...1 4 Getting Started 605 Series Frequency Inverter ...
Страница 22: ...2 6 An Overview of the Inverter 605 Series Frequency Inverter ...
Страница 34: ...3 12 Installing the Inverter 605 Series Frequency Inverter ...
Страница 48: ...4 14 Operating the Inverter 605 Series Frequency Inverter ...
Страница 156: ...8 2 Routine Maintenance and Repair 605 Series Frequency Inverter ...
Страница 198: ...12 12 Certification for the Inverter 605 Series Frequency Inverter ...
Страница 202: ...13 4 Application Notes 605 Series Frequency Inverter ...
Страница 204: ...14 2 Serial Communications 605 Series Frequency Inverter ...