11-2
Technical Specifications
605 Series Frequency Inverter
Cabling Requirements for EMC Compliance
605
605
605
605
Type
Type
Type
Type
Power Supply
Power Supply
Power Supply
Power Supply
Cable
Cable
Cable
Cable
Motor Cable
Motor Cable
Motor Cable
Motor Cable
External AC
External AC
External AC
External AC
Supply EMC
Supply EMC
Supply EMC
Supply EMC
Filter to Inverter
Filter to Inverter
Filter to Inverter
Filter to Inverter
Cable
Cable
Cable
Cable
Brake Resistor
Brake Resistor
Brake Resistor
Brake Resistor
Cable
Cable
Cable
Cable
Signal/Control
Signal/Control
Signal/Control
Signal/Control
Cable
Cable
Cable
Cable
Cable Type
Cable Type
Cable Type
Cable Type
(for EMC Compliance)
(for EMC Compliance)
(for EMC Compliance)
(for EMC Compliance)
A & B
A & B
A & B
A & B
Unscreened
Screened/
armoured
Screened/
armoured
Screened/
armoured
Screened
Segregation
Segregation
Segregation
Segregation
A & B
A & B
A & B
A & B
From all
other wiring
(clean)
From all other wiring (noisy)
From all other
wiring (sensitive)
Length Limitations
Length Limitations
Length Limitations
Length Limitations
With Internal AC Supply
With Internal AC Supply
With Internal AC Supply
With Internal AC Supply
EMC Filter
EMC Filter
EMC Filter
EMC Filter
A
AA
A
BBBB
Unlimited
25 metres
50 metres
25 metres
25 metres
25 metres
25 metres
Length Limitations
Length Limitations
Length Limitations
Length Limitations
With External AC Supply
With External AC Supply
With External AC Supply
With External AC Supply
EMC Filter
EMC Filter
EMC Filter
EMC Filter
A
AA
A
Unlimited
Refer to
“External AC
Supply (RFI)
Filters” table
0.3 metres
25 metres
25 metres
Screen to Earth
Screen to Earth
Screen to Earth
Screen to Earth
Connection
Connection
Connection
Connection
A & B
A & B
A & B
A & B
Both ends
Both ends
Both ends
Inverter end only
Fuse Rating and Recommended Wire Sizes
Local wiring regulations always take precedence.
* European wire sizes are based on EN60204-1 (1993) for PVC single-core cable bunched or
in trunking given a 70
ºC maximum conductor temperature under normal conditions in a 45ºC
ambient.
North American wire sizes are based on NEC/NFPA-70 for ampacities of thermoplastic-
insulated (60ºC) copper conductors assuming not more than three current-carrying conductors in
raceway or cable, based on ambient temperature of 30ºC. The wire sizes allow for an ampacity
of 125% of the rated input and output amperes for motor branch-circuit conductors as specified
in NEC/NFPA-70.
Output
Output
Output
Output
Input
Input
Input
Input
605
605
605
605
Type
Type
Type
Type
Voltage
Voltage
Voltage
Voltage
(V)
(V)
(V)
(V)
No. of
No. of
No. of
No. of
Phases
Phases
Phases
Phases
Motor
Motor
Motor
Motor
Power
Power
Power
Power
(kW)
(kW)
(kW)
(kW)
Output
Output
Output
Output
Current
Current
Current
Current
(A)
(A)
(A)
(A)
* European
* European
* European
* European
Wire Size
Wire Size
Wire Size
Wire Size
(45ºC)
(45ºC)
(45ºC)
(45ºC)
(mm²)
(mm²)
(mm²)
(mm²)
North
North
North
North
American
American
American
American
Wire Size
Wire Size
Wire Size
Wire Size
(AWG)
(AWG)
(AWG)
(AWG)
Input
Input
Input
Input
Current
Current
Current
Current
(A)
(A)
(A)
(A)
Input Fuse
Input Fuse
Input Fuse
Input Fuse
Rating (A)
Rating (A)
Rating (A)
Rating (A)
* European
* European
* European
* European
Wire Size
Wire Size
Wire Size
Wire Size
(45ºC)
(45ºC)
(45ºC)
(45ºC)
(mm²)
(mm²)
(mm²)
(mm²)
North
North
North
North
American
American
American
American
Wire Size
Wire Size
Wire Size
Wire Size
(AWG)
(AWG)
(AWG)
(AWG)
A
220-240 1
0.75
4.0
0.75
14
8.0
10.0
1.5
14
A
220-240 3
0.75
4.0
0.75
14
5.0
10.0
1.5
14
A
220-240 1
1.5
7.0
1.0
14
15.0
20.0
4.0
12
A
220-240 3
1.5
7.0
1.0
14
9.0
10.0
1.5
14
B
220-240 1
2.2
10.5
1.5
14
23.0
25.0
6.0
10
B
220-240 3
2.2
10.5
1.5
14
12.0
15.0
(16.0 for
Europe)
2.5
14
B
220-240 3
3.7
16.5
2.5
10
16.0
20.0
4.0
12
B
380-460 3
0.75
2.5
0.75
14
3.0
10.0
1.5
14
B
380-460 3
1.5
4.5
0.75
14
6.0
10.0
1.5
14
B
380-460 3
2.2
5.5
0.75
14
8.0
10.0
1.5
14
B
380-460 3
3.7
9.5
1.5
14
11.0
15.0
(16.0 for
Europe)
2.5
14
Содержание 605 Series
Страница 16: ...1 4 Getting Started 605 Series Frequency Inverter ...
Страница 22: ...2 6 An Overview of the Inverter 605 Series Frequency Inverter ...
Страница 34: ...3 12 Installing the Inverter 605 Series Frequency Inverter ...
Страница 48: ...4 14 Operating the Inverter 605 Series Frequency Inverter ...
Страница 156: ...8 2 Routine Maintenance and Repair 605 Series Frequency Inverter ...
Страница 198: ...12 12 Certification for the Inverter 605 Series Frequency Inverter ...
Страница 202: ...13 4 Application Notes 605 Series Frequency Inverter ...
Страница 204: ...14 2 Serial Communications 605 Series Frequency Inverter ...