![Eurotherm 605 Series Скачать руководство пользователя страница 139](http://html.mh-extra.com/html/eurotherm/605-series/605-series_product-manual-installation-and-instructions_2440552139.webp)
Programming Your Application
6-71
605 Series Frequency Inverter
UNDERLAP COMP
The underlap compensation function block
ensures sinusoidal motor current at low
motor speeds.
This significantly reduces `cogging’
(rough/pulsating motor rotation) at low speeds.
Underlap compensation is especially desirable
in lift or hoist applications.
Functional Description
Underlap is the bridge switching delay required for correct operation of the inverter power
electronic output stage. The delay causes errors in the inverter output voltage leading to non-
sinusiodal motor currents at low motor speeds. The result is motor cogging, and a loss of motor
torque at low speeds.
Underlap compensation removes underlap errors, and provides consistent motor operation
regardless of motor speed.
MMI Menu Map
1
SETUP PARAMETERS
2
FUNCTION BLOCKS
3
MOTOR CONTROL
4
UNDERLAP COMP
ULC ENABLE
UNDERLAP COMP
TRUE – [600] ENABLE
–
Parameter Descriptions
ENABLE
Range: FALSE / TRUE
Enables underlap compensation when set to TRUE.
Содержание 605 Series
Страница 16: ...1 4 Getting Started 605 Series Frequency Inverter ...
Страница 22: ...2 6 An Overview of the Inverter 605 Series Frequency Inverter ...
Страница 34: ...3 12 Installing the Inverter 605 Series Frequency Inverter ...
Страница 48: ...4 14 Operating the Inverter 605 Series Frequency Inverter ...
Страница 156: ...8 2 Routine Maintenance and Repair 605 Series Frequency Inverter ...
Страница 198: ...12 12 Certification for the Inverter 605 Series Frequency Inverter ...
Страница 202: ...13 4 Application Notes 605 Series Frequency Inverter ...
Страница 204: ...14 2 Serial Communications 605 Series Frequency Inverter ...