Programming Your Application
6-75
605 Series Frequency Inverter
Operation
Operation
Operation
Operation
Description
Description
Description
Description
ON DELAY
A programmable delay between receiving and outputting a Boolean TRUE
signal.
INPUT A becoming TRUE starts the delay timer. INPUT B sets the duration
of the delay. At the end of the duration, OUTPUT becomes TRUE unless
INPUT A has reverted to FALSE. Setting INPUT C to TRUE (
≠
0) inverts the
output.
OFF DELAY
A programmable delay between receiving and outputting a Boolean FALSE
signal.
INPUT A becoming FALSE starts the delay timer. INPUT B sets the duration
of the delay. Setting INPUT C to TRUE (
≠
0) inverts the output. At the end of
the duration, OUTPUT becomes FALSE unless INPUT A has reverted to
TRUE.
input A
output
input C FALSE
input C TRUE
Target time (input B)
t
input A
output
input C FALSE
input C TRUE
Target time (input B)
t