5-18
The Operator Station
605 Series Frequency Inverter
To Deactivate Password Protection
Enter the current password in the ENTER PASSWORD
parameter. Press the
E
key to exit.
Note:
You can also choose to have the password protect the
entire OPERATOR menu, or just the SETPOINT
(LOCAL) parameter. Under default conditions these
are not protected. Refer to Chapter 6: “Programming
Your Application” - PASSWORD.
Selecting Parameters for the Operator Menu
The diagram below shows the default view of this menu.
The selected “view level” has no effect on this menu, it is always available.
The default setting for the OPERATOR menu is to display 8 parameters, however it actually
contains 16 parameters. Except for parameter No. 1 which is fixed as the SETPOINT parameter
and the last parameter which is always ENTER PASSWORD, the remaining 14 parameters can
be changed to display any diagnostic or configurable parameter, (also refer to “Creating Custom
Screens” below).
1.
Select the OPERATOR MENU menu at level 4. To
view this menu the Operator Station must have
ADVANCED view level selected.
2.
Press the
M
key to reveal the STARTUP SCREEN
parameter (this is described below).
Press the down (
∇
∇
∇
∇
)
arrow to display the
OPERATOR MENU 2 parameter. You select a
parameter for display by entering its tag number
into one of the OPERATOR MENU parameters;
press the
M
key and use the up (
∆∆∆∆
)
and down (
∇
∇
∇
∇
)
keys to set the tag number. Press the
E
key to exit
the parameter.
For more details on customising this menu to your application refer to Chapter 6: “Programming
Your Application” - OPERATOR MENU.
Selecting a Startup Screen
The STARTUP SCREEN parameter selects which of the
OPERATOR MENU parameters will be used as the
Startup screen. Press the
M
key and use the up (
∆∆∆∆
)
and
down (
∇
∇
∇
∇
)
keys to set the screen number. Press the
E
key
to exit the parameter. The example shown has
OPERATOR MENU 1 selected (this is the “fixed”
OPERATOR MENU parameter that always displays the
SETPOINT parameter). Setting the STARTUP SCREEN to an OPERATOR MENU parameter
whose tag number is set to zero will cause the STARTUP SCREEN to revert to OPERATOR
MENU 1.
HEALTH
LOCAL
SEQ
REF
1
1
0000
ENTER PASSWORD
SETPOINT (REMOTE)
SPEED DEMAND
DRIVE FREQUENCY
MOTOR CURRENT
LOAD
DC LINK VOLTS
CURRENT LIMITING
ENTER PASSWORD
OPERATOR
menu at level 1
HEALTH
LOCAL
SEQ
REF
1
1
= 115
OPERATOR MENU 2
HEALTH
LOCAL
SEQ
REF
1
1
= 0
OPERATOR MENU 16
HEALTH
LOCAL
SEQ
REF
1
1
1
STARTUP SCREEN
Содержание 605 Series
Страница 16: ...1 4 Getting Started 605 Series Frequency Inverter ...
Страница 22: ...2 6 An Overview of the Inverter 605 Series Frequency Inverter ...
Страница 34: ...3 12 Installing the Inverter 605 Series Frequency Inverter ...
Страница 48: ...4 14 Operating the Inverter 605 Series Frequency Inverter ...
Страница 156: ...8 2 Routine Maintenance and Repair 605 Series Frequency Inverter ...
Страница 198: ...12 12 Certification for the Inverter 605 Series Frequency Inverter ...
Страница 202: ...13 4 Application Notes 605 Series Frequency Inverter ...
Страница 204: ...14 2 Serial Communications 605 Series Frequency Inverter ...