Operation
ets-lindgren.com
Lower Limit/CCW Limit
Displays the current setting for the device. Lower Limit is for towers and
CCW limit is for turntables.
To change the current setting, press
Lower limit/ CCW Limit
, enter the
new number at the keypad, and then press
degr.
(for turntable) or
cm
(for tower).
Current Position
Displays the current position for the device.
To change the current setting, press
Current position
, enter the
new number at the keypad, and then press
degr.
(for turntable) or
cm
(for tower).
Scan Cycle Count
Displays the scan cycle count, the number of times the positioner will
move between the upper and lower limit while scanning.
To change the current setting press
Scan Cycle Count
, enter the new
number at the keypad and press
Enter
.
Step Size
Displays the step size, the number of degrees or cm the positioner will
move in Step mode.
To change the current setting press
Step Size
, enter the new number at
the keypad and press
Enter
.
Содержание ETS-Lindgren EMControl 7006-001
Страница 1: ...Model 7006 001 EMControl Positioner Controller Plug In Card User Manual...
Страница 8: ...viii ets lindgren com This page intentionally left blank...
Страница 12: ...12 Introduction ets lindgren com This page intentionally left blank...
Страница 16: ...16 Specifications ets lindgren com This page intentionally left blank...
Страница 18: ...18 EMControl Plug In Card Installation ets lindgren com This page intentionally left blank...
Страница 88: ...88 EMControl Command Set ets lindgren com This page intentionally left blank...
Страница 90: ...90 Warranty ets lindgren com This page intentionally left blank...