58
EMControl Command Set
ets-lindgren.com
S#
Description:
Changes the speed selection of a two-speed or variable speed
device.
Devices:
Turntables, towers
Syntax:
S#
#
: For a two-speed device: 1=high, 2=low
For variable speed devices: 1
–8=preset speed selection
Response:
OK
, or an error (error number)
Example:
Write
sdS1\n
: Change to high speed/preset 1
See Also:
S?
,
SS#
,
SS#?
S?
Description:
Queries the speed selection of a two-speed or variable speed
device.
For a two-speed device, a single digit value of
1
is returned if in
high-speed mode. Otherwise, a value of
2
is returned for
low-speed mode.
For a variable speed device, returns a single digit value of 1
–8 to
report the currently-selected speed preset.
Devices:
Turntables, towers
Syntax:
S?
Response:
<speed select>
: Value between 1 and 8 indicating the
currently-selected speed setting
Example:
Write
sdS?\n
: Query turntable speed
Read response
Response is
3\n
: Speed setting is 3
See Also:
S#
,
SS#
,
SS#?
Содержание ETS-Lindgren EMControl 7006-001
Страница 1: ...Model 7006 001 EMControl Positioner Controller Plug In Card User Manual...
Страница 8: ...viii ets lindgren com This page intentionally left blank...
Страница 12: ...12 Introduction ets lindgren com This page intentionally left blank...
Страница 16: ...16 Specifications ets lindgren com This page intentionally left blank...
Страница 18: ...18 EMControl Plug In Card Installation ets lindgren com This page intentionally left blank...
Страница 88: ...88 EMControl Command Set ets lindgren com This page intentionally left blank...
Страница 90: ...90 Warranty ets lindgren com This page intentionally left blank...