ets-lindgren.com
EMControl Command Set
69
TWR
Description:
Selects tower mode of operation.
Allows the selection of both normal and bore sight towers. In the
bore sight mode of operation, the separation distance is taken
into account when reporting boom height.
This command is intended to allow automated configuration of
the EMControl and should not be used by most programs.
Devices:
Turntables, towers
Syntax:
TWR <NRM/BOR>
NRM
: Normal tower
BOR
: Bore sight tower
Response:
OK
, or an error (error number)
Example:
Write
sdTWR NRM\n
: Change device to a normal tower
See Also:
TT
,
TYP?