PARM:BCT
Description:
Sets the bore sight correction.
Devices:
Bore Sight Towers
Syntax:
PARM:BCT X
X
: Value of bore sight correction
0
: Standard
1
: Alternate
2
: Dual-Mast
Response:
OK
, or an error (error number)
Example:
Write
PARM:BCT 1\n
: Set bore sight correction to
Alternate
See Also:
PARM:BCT?
PARM:BCT?
Description:
Queries the bore sight correction.
Devices:
Bore Sight Towers
Syntax:
PARM:BCT?
Response:
<correction>
: Value of boresight correction
0
: Standard
1
: Alternate
2
: Dual-Mast
Example:
Write
sdPARM:BCT?\n
: Query bore sight correction
Read response
Response is
1\n
: Bore sight correction is Alternate
See Also:
PARM:BCT