EMControl Command Set
49
LL
Description:
Changes the lower limit of the device. The specified value must
be less than the upper limit and between
–999 and 999.
This command simultaneously affects the horizontal and
vertical limits.
Devices:
Towers
Syntax:
LL [+/
–] XXX
+
: Optional for positive values
–
: Necessary for negative values
XXX
: Decimal value for the lower limit to be set in
centimeters. Leading zeroes are optional.
Response:
OK
, or an error (error number)
Example:
Write
sdLL 208\n
: Change both the horizontal and vertical
polarization lower limits of the tower to 208 cm.
See Also:
LL?