Chapter 10: System Messages
179
EVS5200_DOC_SOP_DS850
7003007 - Invalid
PRECINCT ID.
X
When a ballot is scanned, this error is
logged if the ballot has an invalid
precinct identification.
Note:
An actual
name (e.g. Precinct, Borough, etc.) will
appear in the place of “Precinct label.
The Scanner should divert such a ballot to the
Top Out-stack Bin, identifying it as “unknown”.
7003008 - Ballot data
missing.
X
When a ballot is scanned, this error is
logged if required ballot data is missing
from the ballot.
The Scanner should divert such a ballot to the
Top Out-stack Bin, identifying it as “unknown”.
7003009 - Invalid ballot
ID.
X
When a ballot is scanned, this error is
logged if the ballot has an invalid ballot
identification.
The Scanner should divert such a ballot to the
Top Out-stack Bin, listing it as “ballot ID invalid”.
7003010 - Ballot style
data missing.
X
When a ballot is scanned, this error is
logged if required ballot style data is
missing from the ballot.
The Scanner should divert such a ballot to the
Top Out-stack Bin, identifying it as an
“unknown”.
7003012 - Ballot image
data missing.
X
X
When the 'Export Files’ process cannot
locate expected ballot image data on
the Scanner, this error occurs.
Select 'Export Files' again. If this error keeps
recurring, contact an ES&S Customer Service
Representative for assistance.
7003013 - Business data
missing.
X
X
When one of the export processes (e.g.
'Export Results'), selected from the
'Results' menu screen, cannot locate the
related business data (e.g. eba.hdr file)
for export, this error occurs.
Select the same export process again. If this
error keeps recurring, contact an ES&S Customer
Service Representative for assistance.
7003014 - Ballot data
not loaded.
X
X
When loading an election from the
'Setup' screen, this error will occur if the
related ballot data was not loaded as
part of the Election Definition.
From the 'Setup' screen, clear and initialize the
Scanner and then attempt to load the election
again. If this error occurs again, a new ES&S
Election Definition Media Device may be
needed. Contact an ES&S Customer Service
Representative for assistance.
System Messages
NOTE: A System Halt is a condition which requires the DS850 to be shutdown. It is not a condition which prevents the scanning of ballots.
Message Text
Message
Displayed
Message
Printed
Message
Logged
Results in a
System Halt
Cause
Resolution
Содержание DS850
Страница 1: ...DS850 Operator s Guide Document Version 4 0 Software Version 2 10 Published February 26 2014 ...
Страница 48: ...Chapter 3 DS850 User Interface 42 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 ...
Страница 191: ...Chapter 11 Menu Structure 185 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 Election menu ...
Страница 192: ...Chapter 11 Menu Structure 186 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 Reports menu ...
Страница 193: ...Chapter 11 Menu Structure 187 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 System menu ...
Страница 194: ...Chapter 11 Menu Structure 188 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 Hardware menu ...
Страница 199: ...Index 193 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 ...