Chapter 10: System Messages
144
EVS5200_DOC_SOP_DS850
1009505 - Camera
Interface - Bad CRC
X
X
X
This message appears upon initialization
of the BAPis Image Processor Board
when the Master Control Program
receives a bad CRC (cyclic redundancy
check) from the board, indicating there
is a problem with the accuracy of data
transmitted through the MCP/BAP
Interface communication link.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since the BAPis Board
is a “COTS” (Commercial Off The Shelf) product,
the ES&S Technician may have to contact a BAP
Technician to diagnose the problem.
1009506 - Camera
Interface -
Configuration not
accepted
X
X
X
This message appears upon initialization
of the BAPis Image Processor Board
when the system configuration
parameters, provided through the
MCP/BAP Interface are not accepted by
the board.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since the BAPis Board
is a “COTS” (Commercial Off The Shelf) product,
the ES&S Technician may have to contact a BAP
Technician to diagnose the problem.
1009507 - Camera
Interface - Wrong
device IDD
X
X
X
This message appears upon initialization
of the BAPis Image Processor Board
when board's returned device ID is not
the one expected by the Master Control
Program.
Write down the error message and notify an
appropriate election official. If possible,
shutdown and then turn off the Scanner. Wait 30
seconds and then turn the Scanner back on. If
the problem persists, an ES&S Service Technician
will need to be contacted. Since the BAPis Board
is a “COTS” (Commercial Off The Shelf) product,
the ES&S Technician may have to contact a BAP
Technician to diagnose the problem.
System Messages
NOTE: A System Halt is a condition which requires the DS850 to be shutdown. It is not a condition which prevents the scanning of ballots.
Message Text
Message
Displayed
Message
Printed
Message
Logged
Results in a
System Halt
Cause
Resolution
Содержание DS850
Страница 1: ...DS850 Operator s Guide Document Version 4 0 Software Version 2 10 Published February 26 2014 ...
Страница 48: ...Chapter 3 DS850 User Interface 42 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 ...
Страница 191: ...Chapter 11 Menu Structure 185 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 Election menu ...
Страница 192: ...Chapter 11 Menu Structure 186 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 Reports menu ...
Страница 193: ...Chapter 11 Menu Structure 187 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 System menu ...
Страница 194: ...Chapter 11 Menu Structure 188 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 Hardware menu ...
Страница 199: ...Index 193 EVS5200_DOC_SOP_DS850 Software Version 2 10 Published February 26 2014 ...