POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS
5-3
The Electrode is shorted
to work piece when ma-
chine is turned ON
VRD defective, or short
circuit between torch and
work piece
Switch OFF and ON the power source
to clear the error code
Configuration Error
Defective PCB, incorrect
system software
Have an Accredited ESAB Service
Provider check the power source
Control Panel identifica-
tion
Control Panel identifica-
tion error
Have an Accredited ESAB Service
Provider check the power source
Power Module
Power Module not sym-
metrical
Have an Accredited ESAB Service
Provider check the power source
Table 5-2: Error Message
5.02 Power Source Problems
FAULT
CAUSE
REMEDY
1 Mains supply voltage is ON,
Control panel LED's are
illuminated however unit will
not commence welding when
the torch trigger switch is
depressed.
A
B
Power source is not in the
correct mode of operation.
Faulty torch trigger.
A
B
Set the power source to the correct mode of
operation with the process selection switch.
Repair or replace torch trigger switch/lead.
2 Mains supply voltage is
ON. Indicator light is not lit
and welding arc cannot be
established.
A
B
Primary control fuse is blown.
Broken connection in primary
circuit.
A
B
Replace primary control fuse.
Have an Accredited ESAB Service Provider
check primary circuit.
3 Error Code E01 is displayed
and unit will not commence
welding when the torch trigger
switch is depressed.
Duty cycle of power source has
been exceeded.
Leave the power source switched ON and
allow it to cool. Note that fault indicator must
be extinguished prior to commencement of
welding.
4 Welding output continues when
torch trigger released
A
B
Trigger mode selection is in 4T
(LATCH) mode
Torch trigger leads shorted
A
B
Change to 2T (NORMAL) mode
Repair or replace Torch / trigger lead
5 Welding output voltage is
present when the torch trigger
switch is depressed but arc
cannot be established.
Poor or no work lead contact.
Clean work clamp area and ensure good
electrical contact.
6 Welding output voltage is not
present when torch trigger
depressed
Faulty trigger switch / lead
Repair or replace Torch / trigger lead
7 TIG electrode melts when
arc is struck.
TIG torch is connected to
the Worklead terminal.
Connect the TIG torch to the Electrode
terminal.
8 Arc flutters during TIG
welding.
Tungsten electrode is too
large for the welding current.
Select the correct size of tungsten
electrode.
9 No HF output in HF mode
HF Circuit faulty
Have an Accredited ESAB Service Provider
check HF circuit.
10 Error Code is displayed
Refer to the error code list,
section 3.16
Refer to the error code list, section 3.16
Table 5-3: Power Source Problem
Содержание ET 220i AC/DC
Страница 46: ...ET 220I AC DC INSTALLATION OPERATION AND SETUP Manual 0 5346 3 34 This Page Intentionally Blank...
Страница 68: ...ET 201I AC DC KEY SPARE PARTS 0 5346 6 2 6 01 Key Spare Parts A 12885_AB Figure 6 1 Spare Parts...
Страница 70: ...ET 201I AC DC KEY SPARE PARTS 0 5346 6 4 This Page Intentionally Blank...
Страница 73: ......