![ESAB ET 220i AC/DC Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/esab/et-220i-ac-dc/et-220i-ac-dc_operating-manual_2424782060.webp)
ET 220I AC/DC
BASIC WELDING GUIDE
Manual 0-5346
4-14
FAULT
CAUSE
REMEDY
7 Dirty weld pool
A Electrode contaminated
by contact with work
piece or filler rod
material.
A Clean the electrode by grinding off the
contaminates.
B Work piece surface has
foreign material on it.
B Clean surface.
C Gas contaminated with
air.
C Check gas lines for cuts and loose fitting
or change gas cylinder.
8 Poor weld finish
Inadequate shielding
gas.
Increase gas flow or check gas line for
gas flow problems.
9 Arc start is not smooth.
A Tungsten electrode
is too large for the
welding current.
A Select the right size tungsten electrode.
Refer to Table 4-3 ESAB Tungsten
Electrode Selection Chart.
B The wrong electrode
is being used for the
welding job.
B Select the right tungsten electrode
type. Refer to Table 4-5 ESAB Tungsten
Electrode Selection Chart.
C Gas flow rate is too
high.
C Select the right rate for the welding job.
Refer to Table 4-7.
D Incorrect shielding gas
is being used.
D Select the right shielding gas.
E Poor work clamp
connection to work
piece.
E Improve connection to work piece.
10 Arc flutters during TIG
welding.
Tungsten electrode
is too large for the
welding current.
Select the right size tungsten electrode.
Refer to Table 4-3 ESAB Tungsten
Electrode Selection Chart.
Table 4-7
Содержание ET 220i AC/DC
Страница 46: ...ET 220I AC DC INSTALLATION OPERATION AND SETUP Manual 0 5346 3 34 This Page Intentionally Blank...
Страница 68: ...ET 201I AC DC KEY SPARE PARTS 0 5346 6 2 6 01 Key Spare Parts A 12885_AB Figure 6 1 Spare Parts...
Страница 70: ...ET 201I AC DC KEY SPARE PARTS 0 5346 6 4 This Page Intentionally Blank...
Страница 73: ......