ET 220I AC/DC
INSTALLATION, OPERATION AND SETUP
Manual 0-5346
3-28
Master Reset
!
WARNING
All saved TipTronic jobs will be erased.
All welding and secondary parameters will be restored to the factory setting.
• Press and hold the BACK button (22).
• Press the hold the SAVE button (53).
• All control panel LED’s will light up briefly to confirm the Soft Reset has been completed. After 5 seconds all the control panel
LED’s will light again briefly to confirm the Master Reset has been completed.
T
4T
2T
Art # A_12853
Figure 3-16: Master Reset
Control Panel Test
• Press and hold the BACK button (22).
• Press the FORWARD button (23).
• All control panel LED’s and meter displays will light up for approximately 4 seconds.
Art # A-12854
T
4T
2T
Figure 3-17: Control Panel Test