See the following tables which show the error conditions and
corresponding possible causes:
Table 3-4. Error Condition and the Possible Causes
No.
Error Condition
Possible Causes
1
Paper Out Error
(Refer to Section
3.1.1.1.
)
1. Failure in paper feeding
2. Connector for the PE sensor is disconnected.
3. The PE sensor actuator is acting improperly.
The sensor base is not fixed properly.
4. The PE sensor is defective.
5. ASF dose not move correctly
2
Paper Jam Error
(Refer to Section
3.1.1.2.
)
1. The paper in use is longer than specified.
2. The PE sensor remains on because it is covered with
paper debris or dust.
3. The PE sensor actuator is not acting properly.
The sensor base is not fixed properly.
4. The PE sensor is defective
5. The Hopper Release Lever is not assembled correctly.
3
NO I/C or Ink Out
Error (Refer to
Section3.1.1.3)
1. The counter is not showing the actual remaining ink
level.
2. Ink cartridge sensor actuator is not acting properly.
3. The micro switch is not mounted correctly.
The connector (green) is disconnected.
4. The connector (green, 3-pin) on the small board
directly attached to the printhead surface side is
disconnected. Note the connector (green, 4-pin) is
irrelevant as it is for the encoder.
5. The micro switch is defective.
6. The value for the ink consumption counter in the
EEPROM is destroyed.
4
Maintenance
Error (Refer to
Section 3.1.1.4)
)
Usual waste ink over-flow is requested.
Note this error can be cleared by the special function
through the control panel operation and the Adjustment
program.
5
Fatal Error
(Refer to Section
3.1.1.5)
1. The CR Encorder FFC has come off from the CR
Encorder Sensor board.
The CR Encorder sensor is not mounted in the CR
Assy.
2. The CR liner scale has come off.
The CR liner scale is not placed through the encoder
located at the back of the carriage.
3. The ASF sensor has come off.
The connector for the ASF sensor is not disconnected.
4. The ASF sensor is defective or dose not detect the
ASF HP position caused by any factor.
5. The PF or CR Encorder Sensor is defective or dose
not detect the slite pattern on the each scale.
6. The coil for the CR motor has burnt.
7. The coil for the PF motor has burnt.
8. Coil for the ASF/Pump motor has burnt
9. ASF Gear 32 is disengaged to the Combination Gear
14,28 which is assembled in the DE unit.
10. Torsion Spring 0.618 comes off from the DE Lock
Lever and the hook of DE unit.
Table 3-4. Error Condition and the Possible Causes (continued)
No.
Error Condition
Possible Causes
Содержание Stylus COLOR 1160
Страница 8: ...C H A P T E R PRODUCTDESCRIPTION ...
Страница 28: ...C H A P T E R OPERATINGPRINCIPLES ...
Страница 53: ...C H A P T E R TROUBLESHOOTING ...
Страница 74: ...C H A P T E R DISASSEMBLYANDASSEMBLY ...
Страница 116: ...C H A P T E R ADJUSTMENT ...
Страница 150: ...C H A P T E R MAINTENANCE ...
Страница 160: ...APPENDIX C H A P T E R ...
Страница 171: ...PSON Stylus COLOR 860 1160 Revision C ppendix Circuit Board Component Layout 171 Figure 7 5 C298PNL Component Layout ...