Solitrend MMP20 (Option D)
Managing and archiving concrete formulations
Hauser
39
10
Managing and archiving concrete
formulations
With the correct settings for the CHAR parameter (fine, coarse, normal, special) and G-Set
parameter (core water and additives), the measurement results of the SWZ probe should
correlate relatively well with verified actual values or target values. In order to achieve the
best possible accuracy with the SWZ probe, we recommend that you document the
necessary settings for the handheld terminal if different varieties of concrete are used and
checked repeatedly.
The following list shows one way of archiving the information.
•
Variety of concrete or variety number:
F600TL
• Target raw density: 2.422
• CHAR parameter: coarse
• G-Set parameter: -10
•
Variety of concrete or variety number:
AAV2
• Target raw density: 2.441
• CHAR parameter: normal
• G-Set parameter: -5
•
Variety of concrete or variety number:
163802
• Target raw density: 2.330
• CHAR parameter: normal
• G-Set parameter: -8
•
Variety of concrete or variety number:
3716CL
• Target raw density: 2.367
• CHAR parameter: fine
• G-Set parameter: -5