Solitrend MMP20 (Option D)
Commissioning
Hauser
19
Entering the CHAR parameter
1. Using the navigation keys
, select one of the four possible options for CHAR (fine
C, medium B, coarse A, or gap U)
2. Press Enter to confirm your entry
7.7.3
G-Set fine adjustment for concrete variety with rock type and
core water
The G-Set value is entered in liters/m
3
and can be entered in increments of 1 l/m
3
up
to a maximum of ±50 l/m
3
. Once a G-Set value is identified for a certain type of rock,
it is advisable to archive this value
Entering the G-Set value
1. Using the navigation keys
, set the G-Set value in increments of 1 l/m
3
up to
maximum ±50 l/m
3
2. Press Enter to confirm your entry
Once you have changed or set the raw density, the CHAR parameter and the G-
Set, you are taken automatically to the "Meas" menu when you press the Enter
key .
7.7.4
Measuring in the "Average" operating mode
The following screen appears in the "Meas" menu once the raw density and G-Set values
have been entered. The handheld device generally measures in the "Average" mode and
determines the kiln-dry water content of a fresh concrete sample in liters/m
3
using the
raw density entered.
Starting a single measurement
1. Press the Enter key briefly
The device starts the single measurement and a rotating symbol appears instead
of the battery symbol in the top right-hand corner for the duration of the
measurement process. No other actions can be performed during this time. A
single measurement takes around 2 to 3 s. When the measurement is finished,
the battery symbol appears on the display again.
2. The water content, calculated using the raw density D, is displayed in liters/m
3
on the
screen. The number of individual measurements is displayed below this value in "No.
values".