10.3
Linearization for horizontal cylinder or conical outlet
Start
Chapter 4, Section 4.1
- for mode 5, calibrate according to
the instructions in Chapter 8.2
Claibration/Linearization
Chapter 4, Section 4.2
…
4.4
Chapter 8
Chapter 5
- V0H0 displays volume
- Relays and analogue output must
be set in volume units
Set analogue output signal (optional)
Chapter 6
- Enter settings in the units selected
during calibration or linearization
- V8H2 assigns output 2
Set relay parameters(optional)
Chapter 7
- Relay 1 can be assigned to channel 2
by entering 2 at V1H4
- Relay 2 can be assigned to channel 1
by entering 1 at V5H4
Lock parameter matrix (optional)
Chapter 4, Section 4.6
Reset parameters:
V9H5
Enter »fo«
V3H5/V7H5
Enter »S«
V3H6/V7H6
Select mode
V8H0
0 = Channels 1 and 2
1/2 = Channel 1/2
5 = with reference probe
Level or volume
calibration
V3H0/V7H0
0 = level
1 = volume
Enter tank dia.
V2H7/V6H7
Enter tank volume V2H8/V6H8
Activate
linearization
V2H0/V6H0
1 = horizontal cylinder
Calibration
»Empty« V0H1/V4H1
»Full« V0H2/V4H2
Analogue outputs
Channel 1
V0H3
…
V0H7
Channel 2
V4H3
…
V4H7
Relay outputs
Channel 1
V1H0
…
V1H4
Channel 2
V5H0
…
V5H4
Lock parameter matrix
V8H9
Level or volume
calibration
V3H0/V7H0
0 = level
1 = volume
»Empty« V0H1/V4H1
»Full« V0H2/V4H2
Input mode
V2H1/V6H1
0 = manual
1 = automatic level
Table number
V2H2/V6H2
Enter volume
V2H3/V6H3
Enter level
V2H4/V6H4
Next number
V2H5/V6H5
Activate
linearization
V2H0/V6H0
3 = manual characteristic
Horizontal cylinder
Conical outlet
Silometer FMC 672 Z/677 Z
Chapter 10: Quick Programming Guide
53
Содержание Silometer FMC 672 Z
Страница 6: ...Silometer FMC 672 Z 677 Z Notes on Safety 4...
Страница 59: ...Silometer FMC 672 Z 677 Z Operating matrix...
Страница 62: ...Silometer FMC 672 Z 677 Z Operating matrix...
Страница 63: ...Silometer FMC 672 Z 677 Z Operating matrix...