2
Installation
This Chapter describes:
•
The probes for use with the Silometer FMC 672 Z/677 Z
•
Silometer installation in a rack or Monorack housing
•
Transmitter wiring
•
Sensor connection.
•
Hardware configuration for Commulog VU 260 Z or ZA 67
…
operation
•
Technical data.
Warning!
•
The Silometer FMC 672 Z/677 Z transmitter must be installed outside explosion
hazardous areas.
2.1
Probes and sensors
Table 2.1 lists the sensors most frequently used with the Silometer FMC 672 Z/677 Z
transmitter. In addition to those listed, all special probes which can be used with an
EC 37 Z or EC 47 Z electronic insert can be connected to the transmitter. Installation
hints can be taken from the appropriate Technical Information Sheet.
Sensor contants
EC 37 Z/47 Z inserts are supplied with the sensor constants zero frequency »f
o
« and
sensitivity»S« printed on the name plate. Note these constants and enter them into fields
V3H5/V3H6 and V7H5/V7H6 during commissioning, Section 4.1. This dispenses with the
need for a recalibration of the transmitter on replacement of the sensor or insert.
Principle
Probe
TI sheet
Insert
Capacitance
E 09.83.02
11 302 (Z)
E 02.78.01
11 303 Z
TI 072
11 356
E 02.78.03
11 400
E 10.73.15
11 322 Z
E 11.81.03
21 110
E 10.73.19
21 111
E 10.73.17
21 211
E 10.73.18
21 310 (Z)
E 10.73.20
21 315 (Z)
E 10.73.21
EC 37 Z
EC 47 Z
Impedance
Multicap DC 11, DC 16
EC 37 Z
EC 47 Z
Table 2.1
Selection of probes suitable for
use with the Silometer
FMC 672 Z/677 Z
1
3
6
5
4
2
+
I
II
CA (pF)
C(S)(pF)
17
d4
d4 / z4
7
18
d2
d2 / z2
8
FMC 480 Z
FMC 470 Z
FMC 671 / 672 / 676 / 677 Z
HAA 420 Z
1 MHz
EC 47 Z
Ex
0,652
6,805
S
I
II
f
o
475,3
57,2
EC10015EP 8
BA064E08
Fig. 2.1:
Electronic insert EC 37 Z/
EC 47 Z showing position of
sensor constants
Silometer FMC 672 Z/677 Z
Chapter 2: Installation
10