Channel
1
Channel
2
Type
Cause and Remedy
E 101
…
106
Alarm
Fault in instrument electronics
- Call Hauser Service
E 107
Alarm
Battery voltage too low
- Make back-up of entered parameters immediately
- Have battery changed by trained personel or ring for service
E 201/
202
E 301/
302
Alarm
Fault in probe on channel 1/2 (f < 35 Hz; f > 3000 Hz)
- Check probe and electronic insert
E 400
Alarm
Fault in probe on channels 1 + 2
- Check probe, electronic insert and wiring
- Incorrect mode selected (only one probe)
E 401
E 402
Alarm
Fault in probe or wiring, channel 1/2
- Check probe, electronic insert and wiring
- Incorrect operating mode
E 403
Modes 3 and 5
Alarm
Difference in measured values Channel 1/2 too large
- Check calibration, linearization etc.
E 600
E 601
Warning
PFM transmission internal code check
- can be ignored if it appears only briefly
E 602
E 603
Warning
Linearization does not rise monotonously (volume does not
increase with level)
- Check and re-enter values
E 604
E 605
Warning
Linearization has less than two sets of values
- Enter more values
E 606
E 607
Warning
No stored factory linearization (V2H6/V6H6 = 0)
- Select another linearisation function at V2H0/V6H0
E 608
E 609
Warning
Value in V0H5 greater than that in V0H6 (V4H5 > V4H6)
- Check input
E 610
E 611
Warning
Calibration fault, channel 1 (»empty« level > »full« level)
- Repeat calibration
E 613
E 614
Warning
Instrument in simutation mode, channel 1/2
- Switch back when finished
Table 9.1:
Error messages
Silometer FMC 672 Z/677 Z
Chapter 9: Trouble-Shooting
47
Содержание Silometer FMC 672 Z
Страница 6: ...Silometer FMC 672 Z 677 Z Notes on Safety 4...
Страница 59: ...Silometer FMC 672 Z 677 Z Operating matrix...
Страница 62: ...Silometer FMC 672 Z 677 Z Operating matrix...
Страница 63: ...Silometer FMC 672 Z 677 Z Operating matrix...