Installation
Proline Promass F 300 EtherNet/IP
24
1
2
3
4
5
A0028773
4
Installation in a down pipe (e.g. for batching applications)
1
Supply tank
2
Sensor
3
Orifice plate, pipe restriction
4
Valve
5
Batching tank
DN
Ø orifice plate, pipe restriction
[mm]
[in]
[mm]
[in]
8
³⁄₈
6
0.24
15
½
10
0.40
25
1
14
0.55
40
1½
22
0.87
50
2
28
1.10
80
3
50
1.97
100
4
65
2.60
150
6
90
3.54
250
10
150
5.91
Orientation
The direction of the arrow on the sensor nameplate helps you to install the sensor
according to the flow direction (direction of medium flow through the piping).
Orientation
Recommendation
A
Vertical orientation
A0015591
B
Horizontal orientation, transmitter at
top
A0015589
Exceptions: