Proline Promass F 300 EtherNet/IP
Operation options
63
8.3.7
Calling the parameter directly
A parameter number is assigned to every parameter to be able to access a parameter
directly via the onsite display. Entering this access code in the
Direct access
parameter
calls up the desired parameter directly.
Navigation path
Expert → Direct access
The direct access code consists of a 5-digit number (at maximum) and the channel
number, which identifies the channel of a process variable: e.g. 00914-2. In the navigation
view, this appears on the right-hand side in the header of the selected parameter.
1
00914-2
A0029414
1
Direct access code
Note the following when entering the direct access code:
• The leading zeros in the direct access code do not have to be entered.
Example: Enter
"914"
instead of
"00914"
• If no channel number is entered, channel 1 is accessed automatically.
Example: Enter
00914
→
Assign process variable
parameter
• If a different channel is accessed: Enter the direct access code with the corresponding
channel number.
Example: Enter
00914-2
→
Assign process variable
parameter
For the direct access codes of the individual parameters, see the "Description of Device
Parameters" document for the device
8.3.8
Calling up help text
Help text is available for some parameters and can be called up from the navigation view.
The help text provides a brief explanation of the parameter function and thereby supports
swift and safe commissioning.
Calling up and closing the help text
The user is in the navigation view and the selection bar is on a parameter.
1. Press for 2 s.
The help text for the selected parameter opens.
Ent. access code
Enter access code to disable
write protec.
A0014002-EN
19
Example: Help text for parameter "Enter access code"
2. Press + simultaneously.
The help text is closed.
Содержание Proline Promass F 300