Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
062 Sensor connection faulty
1. Check or replace sensor
electronic module (ISEM)
2. If available: Check connection
cable between sensor and
transmitter
3. Replace sensor
• 0x10000DB
• 0x10000DC
• 0x1000113
• 0x1000114
Status signal
F
Diagnostic behavior
Alarm
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
063 Exciter current faulty
1. Check or replace sensor
electronic module (ISEM)
2. If available: Check connection
cable between sensor and
transmitter
3. Replace sensor
0x80002B3
Status signal
S
Diagnostic behavior
Alarm
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
082 Data storage
1. Check module connections
2. Contact service
0x10000E7
Status signal
F
Diagnostic behavior
Alarm
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
083 Memory content
1. Restart device
2. Restore HistoROM S-DAT backup
('Device reset' parameter)
3. Replace HistoROM S-DAT
0x10000A0
Status signal
F
Diagnostic behavior
Alarm
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
140 Sensor signal asymmetrical
1. Check or replace sensor
electronic module (ISEM)
2. If available: Check connection
cable between sensor and
transmitter
3. Replace sensor
0x80000CC
Status signal
S
Diagnostic behavior [from the
factory]
Alarm