Proline Promass F 300 EtherNet/IP
Diagnostics and troubleshooting
207
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
834 Process temperature too high
Reduce process temperature
0x80000C5
Status signal
S
Diagnostic behavior [from the
factory]
Warning
1)
Diagnostic behavior can be changed.
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
835 Process temperature too low
Increase process temperature
0x80000C6
Status signal
S
Diagnostic behavior [from the
factory]
Warning
1)
Diagnostic behavior can be changed.
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
842 Process limit
Low flow cut off active!
1. Check low flow cut off
configuration
0x8000091
Status signal
S
Diagnostic behavior
Warning
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
862 Partly filled pipe
1. Check for gas in process
2. Adjust detection limits
0x8000092
Status signal
S
Diagnostic behavior
Warning
Diagnostic information
Remedy instructions
Coding of diagnostic
information (hex)
No.
Short text
882 Input signal
1. Check input configuration
2. Check external device or process
conditions
• 0x1000031
• 0x1000257
Status signal
F
Diagnostic behavior
Alarm
Содержание Proline Promass F 300
Страница 148: ...Commissioning Proline Promass F 300 EtherNet IP 148 Separator 158 Backlight 158...
Страница 263: ......