Picomag IO-Link
Appendix
Hauser
57
Designation
ISDU
(hex)
ISDU
(dec)
Size
(byte)
Data type Access
Value range
Factory setting
Range
limits
s-End-Value
AEP
Unit selection list from
Unit
Conductivity
0x0290
656
4
float
r/w
1000
-9.9·10⁹
9.9·10⁹
Switch output S-Out 2
Switch Polarity
0x035D
861
2
uint
r/w
PNP=0
NPN=1
PNP
Switch Function
0x0352
850
2
uint
r/w
alarm=0
off=1
on=2
lim.vol.flow=3
lim.temp.=4
lim.vol.=5,
win.vol.flow=6
lims=11
win.temp.=7
win.vol.=8
wins=13
epd=9
alarm
Q-ON-Value
Unit selection list from
Unit
Volumeflow
0x0353
851
4
float
r/w
20/40/80/600 l/min
Q-OFF-Value
Unit selection list from
Unit
Volumeflow
0x0354
852
4
float
r/w
15/30/60/450 l/min
T-ON-Value
Unit selection list from
Unit
Temperature
0x0359
857
4
float
r/w
+ 60 °C
T-OFF-Value
Unit selection list from
Unit
Temperature
0x035A
858
4
float
r/w
+ 50 °C
V-ON-Value
Unit selection list from
Totalizer
0x035B
859
4
float
r/w
0.2/0.4/0.8/6.0 m³
V-OFF-Value
Unit selection list from
Totalizer
0x035C
860
4
float
r/w
0.15/0.3/0.6/4.5 m³
s-ON-Value
Unit selection list from
Conductivity
0x0357
855
4
float
r/w
500
s-OFF-Value
Unit selection list from
Conductivity
0x0358
856
4
float
r/w
200
Voltage output U-Out 2
U - OUT Assign
0x02EE
750
2
uint
r/w
off=0
volume flow=1
temperature=2
temperature
Q-Start-Value
ASP
Unit selection list from
Unit
Volumeflow
0x02EF
751
4
float
r/w
0 l/min
Q-End-Value
AEP
Unit selection list from
Unit
Volumeflow
0x02F0
752
4
float
r/w
25/50/100/750
l/min
T-Start-Value
ASP
Unit
Temperature
0x02F5
757
4
float
r/w
-10 °C
Содержание Picomag IO-Link
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ...www addresses endress com 71552010 71552010...