Tankside Monitor NRF81
Operating menu
Hauser
181
"Pressure" submenu
Navigation
Setup → Advanced setup → Application → Tank configuration
→ Pressure
P1 (bottom) source
Navigation
Setup → Advanced setup → Application → Tank configuration → Pressure → P1
(bottom) source
Description
Defines the source of the bottom pressure (P1).
Selection
• Manual value
• HART device 1 ... 15 pressure
• AIO B1-3 value
• AIO C1-3 value
• AIP B4-8 value
• AIP C4-8 value
Factory setting
Manual value
Additional information
Read access
Operator
Write access
Maintenance
P1 (bottom)
Navigation
Setup → Advanced setup → Application → Tank configuration → Pressure → P1
(bottom)
Description
Shows the pressure at the tank bottom.
Additional information
Read access
Operator
Write access
-
P1 (bottom) manual pressure
Navigation
Setup → Advanced setup → Application → Tank configuration → Pressure → P1
(bottom) manual pressure
Prerequisite
=
Manual value
Description
Defines the manual value of the bottom pressure (P1).
User entry
–25 to 25 bar