Tankside Monitor NRF81
Operating menu
Hauser
121
15.3 "Setup" menu
Navigation
Setup
Device tag
Navigation
Setup → Device tag
Description
Enter a unique name for the measuring point to identify the device quickly within the
plant.
Factory setting
NRF8x
Additional information
Read access
Operator
Write access
Maintenance
Units preset
Navigation
Setup → Units preset
Description
Defines a set of units for length, pressure and temperature.
Selection
• mm, bar, °C
• m, bar, °C
• mm, PSI, °C
• ft, PSI, °F
• ft-in-16, PSI, °F
• ft-in-8, PSI, °F
• Customer value
Factory setting
mm, bar, °C
Additional information
Read access
Operator
Write access
Maintenance
If the
Customer value
option is selected, the units are defined in the following
parameters:
• Distance unit (→ 229)
• Temperature unit (→ 230)
In any other case these are read-only parameters used to indicate the respective unit.