Tankside Monitor NRF81
Operating menu
Hauser
127
Operating mode
Navigation
Setup → Advanced setup → Input/output → HART devices → HART Device(s)
→ Operating mode
Prerequisite
Not available if the HART device is a Prothermo NMT.
Description
Selection of the operation mode PV only or PV,SV,TV,QV. Devines which values are polled
from the connected HART Device.
Selection
• PV only
• PV,SV,TV & QV
• Level
• Measured level
Factory setting
PV,SV,TV & QV
Additional information
Read access
Operator
Write access
Maintenance
Communication status
Navigation
Setup → Advanced setup → Input/output → HART devices → HART Device(s)
→ Communication status
Description
Shows the operating status of the transmitter.
User interface
• Operating normally
• Device offline
Additional information
Read access
Operator
Write access
-
#blank# ( HART PV - designation dependent on device)
Navigation
Setup → Advanced setup → Input/output → HART devices → HART Device(s)
→ #blank#
Description
Shows the first HART variable (PV).
Additional information
Read access
Operator
Write access
-
4)
only visible if the conneced device is a Micropilot