Appendix II
EM15 User’s Manual
138
Code
Parameter Name
Functional description
Default
Property
b7-18 VDO3 output delay
0.0s~3000.0s
0.0s
☆
b7-19 VDO4 output delay
0.0s~3000.0s
0.0s
☆
b7-20 VDO5 output delay
0.0s~3000.0s
0.0s
☆
b7-21 VDO valid state selection
Unit's digit: VDO1.
0: Positive logic valid
1: Reverse logic valid
Ten's digit: VDO2
0, 1 (same as unit's digit)
Hundred's digit: VDO3.
0, 1 (same as unit's digit)
Thousand's digit: VDO4.
0, 1 (same as unit's digit)
Ten thousand's digit: VDO5.
0, 1 (same as unit's digit)
00000
☆
Group b9: Keypad and Display
b9-00
STOP/RESET key
function
0: STOP/RESET key enabled only in operation panel
control
1: STOP/RESET key enabled in any operation mode
1
☆
b9-01
MF.K Key function
selection
0: MF.K key disabled
1: Switchover between operation panel control and
remote command control (terminal or communication)
2: Switchover between forward rotation and reverse
rotation
3: Forward JOG
4: Reverse JOG
5.
Function parameters
3
☆
b9-02
LED display running
parameters 1
0000~FFFF
Bit00: Running frequency 1 (Hz)
Bit01: Setting frequency (Hz)
Bit02: DC bus voltage (V)
Bit03: Output voltage (V)
Bit04: Output current (A)
Bit05: Output power (kW)
Bit06: Output torque (%)
Bit07: DI input status
Bit08: DO output status
Bit09: AI1 voltage (V)
Bit10: AI2 voltage (V)
Bit11: AI3 voltage (V)
Bit12: Count value
Bit13: Length value
Bit14: Load speed display
Bit15: PID setting
H.001F
☆