EM15 User’s Manual
5. Description of Function Codes
103
If b0-11 (frequency command resolution) is 2, the display range is
-320.00Hz ~ 320.00Hz.
U0-30
Main frequency X
Display Range
-300.00Hz~300.00Hz
-3000.0Hz
~
3000.0Hz
It displays the setting of auxiliary frequency X.
⚫
If b0-11 (frequency command resolution) is 1, the display range is -3000.0Hz~3000.0 Hz.
⚫
If b0-11 (frequency command resolution) is 2, the display range is -300.00Hz~300.00 Hz.
U0-31
Auxiliary frequency Y
Display Range
-300.00Hz~300.00Hz
-3000.0Hz
~
3000.0Hz
It displays the setting of auxiliary frequency Y.
⚫
If b0-11 (frequency command resolution) is 1, the display range is -3000.0Hz~3000.0 Hz.
⚫
If b0-11 (frequency command resolution) is 2, the display range is -300.00Hz~300.00 Hz.
U0-34
Motor temperature
Display Range
0°C~200°C
It displays the motor temperature obtained by means of AI3 sampling. For the motor temperature detection details,
see bb-25.
U0-35
Target torque
Display Range
-200.0%~200.0%
It displays the present torque upper limit value.
U0-36
Resolver position
Default
--
Display Range
0~4095
It displays the current resolver position.
U0-37
Power factor angle
Display Range
0~4095
It displays the present power factor angle.
U0-38
ABZ position
Display Range
0~65535
It displays the phase A and B pulse counting of the present ABZ or UVW encoder. This value is four times the
number of pulses that the encoder runs. For example, if the display is 4000, the actual number of pulses that the
encoder runs is 4000/4 = 1000.
The value increase when the encoder rotates in forward direction and decreases when the encoder rotates in
reverse direction. After increasing to 65535, the value starts to increase from 0 again. After decreasing to 0, the
value starts to decrease from 65535 again.
You can check whether the installation of the encoder is normal by viewing U0-37.
U0-39
Target voltage of V/F separation
Display Range
0 V ~ rated motor voltage
U0-40
Output voltage of V/F separation
Display Range
0 V ~ rated motor voltage
They display the target output voltage and present actual output voltage in the V/F separation state. For V/F
separation more details, see the descriptions of group d2.
U0-41
DI input state visual display
Display Range
--
It displays the DI state visually and the display format is shown in the following figure.