5.Description of Function Codes
EM15 User's Manual
102
U0-15
PID setting
Display Range
0~65535
U0-16
PID feedback
Display Range
0~65535
They display the PID setting value and PID feedback value.
⚫
PID setting = PID setting (percentage) ×C0-05
⚫
PID feedback = PID feedback (percentage) × C0-05
U0-18
Input pulse frequency
Display Range
0.00kHz ~100.00 kHz
It displays the high-speed pulse sampled frequency of HDI, in minimum unit of 0.01 kHz.
U0-19
Feedback speed, unit:0.01Hz
Display Range
-3000.0Hz~3000.0 Hz
-300.00Hz~300.00 Hz
It displays the actual output frequency of the frequency inverter.
⚫
If b0-11 (frequency command resolution) is set to 1, the display range is -3000.00~3000.00 Hz.
⚫
If b0-11 (frequency command resolution) is set to 2, the display range is -300.00Hz~300.00 Hz.
U0-20
Remaining running time
Display Range
0.0min~6500.0 min
It displays the remaining running time when the timing operation is enabled. For details on timing operation, refer
to b2-28 ~ b2-30.
U0-21
AI1 voltage before correction
Display Range
0.00V~10.57 V
U0-22
AI2 voltage before correction
Display Range
0.00V~10.57 V
U0-23
AI3 voltage before correction
Display Range
0.00V~10.57 V
They display the AI sampling voltage actual value. The actually used voltage is obtained after linear correction,
which will reduce the deviation between the sampled voltage and the actual input voltage.
For actual corrected voltage, see U0-09, U0-10 and U0-11. Refer to group b8 for the correction mode.
U0-24
Linear speed
Display Range
0.0min~65535m/min
It displays the linear speed of the HDI high-speed pulse sampling. The unit is meter per minute (meter/min). The
linear speed is calculated according to the actual number of pulses sampled per minute and C3-07 (Number of
pulses per meter).
U0-27
Communication setting value
Display Range
-100.00%~100.00%
It displays the data written in by means of the communication address 0x1000.
U0-28
Actual feedback speed
Display Range
-300.00Hz~300.00Hz
-3000.0Hz
~
3000.0Hz
It displays the motor running frequency measured by the encoder.
⚫
If b0-11 (frequency command resolution) is 1, the display range is -3000.0Hz~3000.0 Hz.
⚫
If b0-11 (frequency command resolution) is 2, the display range is -300.00Hz~300.00 Hz.
U0-29
Encoder feedback speed
Display Range
-300.00Hz~300.00Hz
-3000.0Hz
~
3000.0Hz
It displays the motor running frequency measured by the encoder.
If b0-11 (frequency command resolution) is 1, the display range is
-3200.0Hz ~ 3200.0Hz