5.Description of Function Codes
EM15 User's Manual
66
board. In this case, VDOx and DIx are one-to-one mapping relationship.
⚫
If VDO function is set to non-0, the function setting and use of VDOx are the same asDO in group b4.
The VDOx state valid can be set in b7-21. The application examples of VDIx involved the usage of VDOx, and
please see these examples for your reference.
5.9 Group b9: Keypad and Display
b9-00
STOP/RESET key function
Default
1
Setting
Range
0
STOP/RESET key enabled only in operation panel control
1
STOP/RESET key enabled in any operation mode
b9-01
MF.K key function
Default
3
Setting
Range
0
MF.K key disabled
1
Switchover between operation panel control and remote command control
(terminal or communication)
2
Switchover between forward rotation and reverse rotation
3
Forward JOG
4
Reverse JOG
5
Function parameters
MF.K key refers to multifunctional key. You can set the function of the MF.K key by using thisparameter. You can
perform switchover by using this key both in stop or running state.
0: MF.K key disabled
This key is disabled.
1: Switchover between operation panel control and remote command control
(terminal or communication)
You can perform switchover from the present command source to the operation panel control (local operation). If the
present command source is operation panel control, this key is invalid.
2: Switchover between forward rotation and reverse rotation
You can change the direction of the frequency inverter running by using the MF·
K key. It isvalid only when the
present command source is operation panel control.
3: Forward JOG
You can perform forward JOG (FJOG) by using the MF·
K key.
4: Reverse JOG
You can perform reverse JOG (FJOG) by using the MF·
K key.
5: Function parameters
You can viewing function parameters by using the MF·
K key.
BASE
Show all function parameters in sequence
USER
View or modify common user parameters
C
The function parameters that have been modified by a user are shown here.